Enhanced sensitivity electrochemical assay of low-molecular-weight heparins using rotating polyion-sensitive membrane electrodes.

نویسندگان

  • Wei Qin
  • Wei Zhang
  • Kang Ping Xiao
  • Mark E Meyerhoff
چکیده

Use of a novel rotating polycation-sensitive polymer membrane electrode yields sensors that can serve as simple potentiometric titration endpoint detectors for the determination of three FDA approved low-molecular-weight heparin (LMWH) anticoagulant drugs (Fragmin, Normiflo, and Lovenox). The rotating electrode configuration dramatically improves the reproducibility and increases the sensitivity for LMWH determinations by protamine titration. At a rotation speed of 3000 rpm, electrodes with optimized thin (50 microm) polymer membranes doped with dinonylnaphthalene sulfonate (DNNS) respond to low levels of protamine (<2 microg mL(-1)) with good precision (+/-1 mV, N=10), when protamine is infused continuously into a Tris-buffer solution, pH 7.4. When infusing protamine (at 5 microg min(-1)) continuously into solutions containing Fragmin, a clear endpoint is obtained, with the amount of protamine required to reach this endpoint proportional to the level of Fragmin present. A detection limit of less than 0.02 U mL(-1) Fragmin can be obtained via this new method, approximately one order of magnitude lower than that previously reported based on a non-rotating polycation electrode. Similar low detection limits can be achieved for potentiometric titrations of Normiflo and Lovenox. Such titrations can also be carried out in undiluted plasma samples containing the various LMWH species. In this case, detection of the LMWHs at clinically relevant concentrations (>0.2 U mL(-1)) can be readily achieved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Solid-contact electrochemical polyion sensors for monitoring peptidase activities.

We report here on improved solid-contact electrochemical polyion sensors for the detection of polyion protamine. The polymeric membrane sensors were fabricated with a conducting polymer as an ion-electron transduction layer. We observed that decreasing the magnitude of the applied current pulse caused a significant improvement of the sensor sensitivity to low protamine levels. The protamine sen...

متن کامل

Electrochemical Sensing of H2S Gas in Air by Carboxylated Multi-walled Carbon Nanotubes

The electrochemical sensor for detecting hydrogen sulfide was fabricated. H2S gas molecules pass through polytetrafluoroethylene membrane with 0.22 mm pore size. Carboxylated multi-walled carbon nanotubes (MWCNTs-COOH) were used to fabricate working and counter electrodes. It can be seen from Field Emission Scanning Electron Microscopy (FESEM) images of the working electrode that...

متن کامل

The Inkjet Printing of Reducible AgNPs amperometric glucose biosensor Electrodes

The enzymes immobilization of the is crucially effective factor in biosensor preparation. Metal nanoparticles potentially able to immobilize the enzymes according to unique properties including large surface-to-volume ratio, high surface reaction activity, high catalytic efficiency, and strong adsorption ability. A novel and highly sensitive amperometric glucose biosensor was obtained by using ...

متن کامل

Comparison of Heparin Red, Azure A and Toluidine Blue assays for direct quantification of heparins in human plasma

Heparins are are sulfated polysaccharides that have tremendous clinical importance as anticoagulant drugs. Monitoring of heparin blood levels can improve patient safety. In clinical practice, heparins are monitored indirectly by their inhibtory effect on coagulation proteases. Drawbacks of these established methods have stimulated the development of simple direct detection methods with cationic...

متن کامل

Oversulfated chondroitin sulfate: impact of a heparin impurity, associated with adverse clinical events, on low-molecular-weight heparin preparation.

Heparin, a widely used anticoagulant, is being rapidly displaced by low-molecular-weight heparins. Recently, certain lots of heparin have been associated with anaphylactoid-type reactions resulting from contamination with oversulfated chondroitin sulfate. This impurity has also contaminated low-molecular-weight heparins obtained by chemical and enzymatic depolymerization of heparin. The sensiti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical and bioanalytical chemistry

دوره 377 5  شماره 

صفحات  -

تاریخ انتشار 2003