Pulsatile Ocular Blood Flow in Healthy Koreans

نویسندگان

  • Seung Kab Kim
  • Byung Joo Cho
  • Samin Hong
  • Sung Yong Kang
  • Jae Sung Kim
  • Chan Yun Kim
  • Gong Je Seong
چکیده

PURPOSE To determine the normal reference range of pulsatile ocular blood flow (POBF) values in healthy Korean subjects and to find out the factors that may affect them. METHODS A total of 280 eyes of 280 normal subjects were included in this study. Best corrected visual acuity (BCVA), intraocular pressure (IOP), axial length, POBF, systemic blood pressure, and pulse rate were measured. The mean, standard deviation, range, and the 5th and 95th percentiles of POBF were calculated, and the influences of various parameters to POBF were determined by multiple regression analyses. RESULTS The mean POBF value was 766.0+/-221.6 microl/min in men and 1021.1+/-249.5 microl/min in women. The 5th and 95th percentiles for POBF values were 486.0 microl/min and 1140.0 microl/min in men and 672.0 microl/min and 1458.0 microl/min in women. The POBF values were significantly influenced by gender, mean blood pressure, pulse rate, and axial length. CONCLUSIONS Even though the POBF values were influenced by gender, BP, and axial length, we could define the normal reference range of POBF in healthy Koreans.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of Pulsatile Non-Newtonian Blood Flow Through Abdominal Aorta and Renal Arteries Incorporating Fluid- Structure Interaction

Background: The interaction between the blood and the vessel wall is of great clinical interest in studying cardiovascular diseases, the major causes of death in developed countries.Objective: To understand the effects of incorporating fluid-structure interaction into the simulation of blood flow through an anatomically realistic model of abdominal aorta and renal arteries reconstructed from CT...

متن کامل

Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer.

AIMS To investigate the effect of central corneal thickness and corneal curvature on intraocular pressure measurements using the pulsatile ocular blood flow tonograph and the Goldmann applanation tonometer, and to assess the agreement between the pulsatile ocular blood flow tonograph and the Goldmann applanation tonometer in intraocular pressure measurement. METHODS 479 subjects underwent int...

متن کامل

PULSATILE MOTION OF BLOOD IN A CIRCULAR TUBE OF VARYING CROSS-SECTION WITH SLIP FLOW

Pulsatile motion of blood in a circular tube of varying cross-section has been developed by considering slip flow at the tube wall and the blood to be a non- Newtonian biviscous incompressible fluid. The tube wall is supposed to be permeable and the fluid exchange across the wall is accounted for by prescribing the normal velocity of the fluid at the tube wall. The tangential velocity of the fl...

متن کامل

Effect of six non-Newtonian viscosity models on hemodynamic parameters of pulsatile blood flow in stenosed artery

A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with non-Newtonian models using ADINA. Blood flow was considered laminar, and the arterial wall was considered rigid. Studied stenosis severities were 30, 50, and 70% of the cross-section...

متن کامل

The influence of sex difference in measurements with the Langham Ocular Blood Flow System.

PURPOSE To assess sex difference and parameters possibly accounting for such a difference in healthy subjects evaluated by means of the Langham Ocular Blood Flow (OBF) System. METHODS Pulse amplitude of intraocular pressure (IOP) and pulsatile ocular blood flow (POBF) as measured with the Langham OBF System were assessed in 86 healthy men and 69 healthy women. RESULTS Compared to men, women...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 22  شماره 

صفحات  -

تاریخ انتشار 2008