Stress distribution in the abutment and retention screw of a single implant supporting a prosthesis with platform switching.

نویسندگان

  • Angel Alvarez-Arenal
  • Luis Segura-Mori
  • Ignacio Gonzalez-Gonzalez
  • Angel Gago
چکیده

PURPOSE Three-dimensional finite element analysis was conducted to evaluate and compare the stress distribution in the abutment and retention screw of implant-supported single crowns with platform switching and with a conventional platform under vertical and oblique loading. MATERIALS AND METHODS Two finite element models were created simulating an osseointegrated implant (4 × 10 mm, platform 4.1 mm) embedded in jawbone. One model simulated a 4-mm-diameter abutment connection (conventional model) and the other represented a 3.8-mm-diameter abutment connection (platform-switched model). A crown with a cobalt-chromium framework and feldspathic porcelain veneering was applied to the titanium abutment. Static vertical and oblique loads were applied to the crown, with a maximum load of 150 N. RESULTS In both models, the highest stress values occurred in the abutment during vertical and oblique loading. Nevertheless, the von Mises stresses in the abutment and the retention screw were lower in the platform-switched model than in the conventional model. During axial loading, the abutment and screw supported slightly less stress in the conventional model than in the platform-switched model. Increases in the angle of force application caused a progressive increase in stresses in the abutment and screw in both models. The maximum stress was distributed at the margin and transgingival area of the abutment and on two-thirds of the flat area and the first threads of the retention screw in both models. CONCLUSIONS Platform switching reduced the stress values on the abutment and retention screw of a single-unit prosthesis during oblique loading. Regardless of whether platform switching was employed, the stress on the abutment and screw gradually increased as the loading direction changed from vertical to 45 degrees oblique. The locations and distributions of stresses were similar in both models.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating the Frequency of Implant-Supported Fixed Prosthesis Complications in Yazd Dental School in 2020

Introduction: Evaluating the frequency of complications in implant supported prosthesis such as screw loosening and porcelain fracture is important for prevention and management of these problems. The purpose of this study was to evaluate the frequency of implant-supported fixed prosthesis complications in Yazd dental school  in 2020. Methods: In this descriptive cross-sectional study, the pat...

متن کامل

Abutment fracture and the technique Used to Remove the fracture portion of the Abutmet: Case Report

Abstract This clinical report presents a case of abutment fracture, due to occlusal overload, occurred with an implant-supported restoration on right mandibular first molar of a female patient. After 6 months of prosthetic reconstruction implants, the patient returned to the clinic due to the loss of implant crown. The fractured fragment of the abutment with the screw protec...

متن کامل

Effect of pontic width on stress distribution in abutment teeth and their supporting structures by finite element analysis

Effect of pontic width on stress distribution in abutment teeth and their supporting structures by finite element analysis Dr. J. Ghanbarzadeh* - Dr. MR. Sabooni* - Dr. M. Keshavarz** * Assistant Professor of Dental Prostheses Dept., Faculty of Dentistry, Mashhad University of Medical Sciences. ** Assistant Professor of Dental Prostheses Dept., Faculty of Dentistry, Kerman University of Medical...

متن کامل

Effect of Abutment Height Difference on Stress Distribution in Mandibular Overdentures: A Three-Dimensional Finite Element Analysis

Background and Aim: Implant-supported overdentures are a treatment option for edentulous patients. One of the important factors in determining the prognosis of overdenture treatment is to control the distribution of stress in the implant-bone and attachment complex. This study assessed the effect of implant abutment height difference on stress distribution in mandibular overdentures. Materials...

متن کامل

مطالعه تنش‌های اطراف ایمپلنت به روش اجزای محدود در بریج‌های با ساپورت دندان/ایمپلنت در شرایط اتصال سخت و غیرسخت در پروتزهای سمان شونده

Background and Aims: Freestanding fixed partial prosthesis is considered the first choice whenever possible. However, anatomical limitations for implants and other reasons may create situation in which it would be preferable to connect the implants to teeth. A biomechanical dilemma in a tooth/implant-supported system comes from dissimilar mobility. This disparity cause the bridge to function as...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 28 3  شماره 

صفحات  -

تاریخ انتشار 2013