Trace analysis of polycyclic aromatic hydrocarbons using gas chromatography-mass spectrometry based on nanosecond multiphoton ionization.

نویسندگان

  • Adan Li
  • Tomohiro Uchimura
  • Hiroko Tsukatani
  • Totaro Imasaka
چکیده

Gas chromatography/resonance-enhanced multiphoton ionization/time-of-flight mass spectrometry (GC/REMPI-TOFMS) using an ultraviolet nanosecond laser was employed in the trace analysis of polycyclic aromatic hydrocarbons (PAHs). A standard sample that contained 16 PAHs on the priority list of the Environmental Protection Agency of the United States of America (U.S. EPA) was measured. A sample of river water that had been pretreated by means of solid-phase extraction was analyzed by GC/MS based on electron impact ionization (EI) and REMPI to evaluate the performance of the analytical instrument. The results suggested that REMPI is superior to EI for soft ionization, and suppresses the background signal due to aliphatic hydrocarbons. Thus, GC/REMPI-TOFMS is a more reliable method for the determination of PAHs present in the environment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of persistent organic pollutants at sub-femtogram levels using a high-power picosecond laser for multiphoton ionization in conjunction with gas chromatography/time-of-flight mass spectrometry.

A low-energy, high-repetition-rate picosecond laser (40 µJ, 20 kHz, 258 nm) was used for multiphoton ionization (MPI) in gas chromatography/time-of-flight mass spectrometry to quantitatively determine dioxins (DXNs) and polycyclic aromatic hydrocarbons (PAHs). The sensitivity of the technique was compared with that obtained using a high-energy, low-repetition-rate femtosecond laser (86 µJ, 1 kH...

متن کامل

Simultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry

Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...

متن کامل

Simultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry

Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...

متن کامل

Determination of petroleum hydrocarbons and polycyclic aromatic hydrocarbons in sludge from wastewater treatment basins.

Screening by gas chromatography with flame ionization detection and gas chromatography-mass spectrometry has been carried out on sludge extracts of wastewater treatment basins. Soxhlet extraction with trichlorotrifluoroethane was applied. The yields for petroleum hydrocarbons and PAH recovery were high, usually in excess of 90%. The proposed investigations permit a quick assessment of petroleum...

متن کامل

Simultaneous analysis of phthalates, adipate and polycyclic aromatic hydrocarbons in edible oils using isotope dilution-gas chromatography-mass spectrometry.

A method for simultaneous determination of 12 priority phthalates, adipate and polycyclic aromatic hydrocarbons (PAHs) in edible oils by isotope dilution-gas chromatography-mass spectrometry (ID-GC-MS) was developed for fast, accurate and trace analysis. The extraction and clean-up procedures were optimised, and using stable isotope-labelled internal standards for each analyte, relative standar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 26 8  شماره 

صفحات  -

تاریخ انتشار 2010