No correlation between intraocular pressure and intracranial pressure.
نویسندگان
چکیده
A recent study has reported an excellent correlation between intraocular pressure (IOP) and intracranial pressure (ICP), suggesting that measurement of IOP may serve as a noninvasive means to determine ICP. To reexamine the relation between IOP and ICP, we reviewed the medical records of all patients who underwent lumbar puncture between 1991 and 2007 in the neuro-ophthalmology clinic at the University of California San Francisco. Data for IOP and ICP were available for 55 patients. There was no correlation between IOP and ICP (Pearson correlation coefficient, r = 0.07; p = 0.59). IOP measurement is not a useful substitute for ICP measurement.
منابع مشابه
Noninvasive measurement of intracranial pressure: is it possible?
BACKGROUND Some publications suggest a strong correlation between the intracranial pressure and the intraocular pressure. Other studies claim no correlation between these two physiologic variables. Our aim was to study whether the tonometry could be a useful method to evaluate intracranial pressure in patients with suspected intracranial abnormality. METHODS We evaluated the correlation betwe...
متن کاملAssociations between intracranial pressure, intraocular pressure and mean arterial pressure in patients with traumatic and non-traumatic brain injuries.
INTRODUCTION Anatomical proximity of the eye and the intracranial space is a fact but the existence of physiological and pathophysiological relationships between them is elusive. The objective of this study was to explore anatomical and pathophysiological interactions between the eye and the intracranial space and to assess clinical utility of intraocular pressure measurement in estimation of i...
متن کاملEvaluation of the diurnal intraocular pressure fluctuations and blood pressure under dehydration due to fasting
Introduction: This study aimed to investigate the diurnal intraocular pressure fluctuations under dehydration conditions and the relationship between the intraocular pressure fluctuations and blood pressure. Methods: The intraocular pressures (IOP), body weights, as well as systolic and diastolic blood pressures (SBP, DBP) of 36 fasting healthy volunteers were recorded at 8:00 a.m. and 5:00 p.m...
متن کاملThe Correlation between Glucose and Lipid Biomarkers Variations with biometric characteristics and Intraocular Pressure Changes during Ramadan Fasting
Introduction: The aim of present study was to assess the correlation between glucose and lipid biomarkers variations with biometric characteristics and intraocular pressure changes following Ramadan fasting. Methods: A total of 100 healthy fasting volunteers were enrolled in the study. Of them, 89 subjects completed the study with respect to inclusion and exclusion criteria. Right eye ocular ax...
متن کاملPoor correlation between intracranial pressure and intraocular pressure by hand-held tonometry
PURPOSE The aim of this study is to provide data on the controversial issue of whether handheld measurements of intraocular pressure (IOP) are capable of accurately predicting elevated intracranial pressure (ICP) in patients undergoing lumbar puncture (LP). METHODS All patients over the age of 18 years who underwent an LP in the emergency or neurological departments at the Tel Aviv Medical Ce...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of neurology
دوره 64 2 شماره
صفحات -
تاریخ انتشار 2008