Influence of polysulfone and hemophan hemodialysis membranes on phagocytes.

نویسندگان

  • L Kubala
  • M Cíz
  • V Soska
  • J Cerný
  • A Lojek
چکیده

The aim of the study was to compare the effect of hemophane and polysulfone membranes on the phagocyte-derived production of reactive oxygen species (ROS) as well as on neutrophil CD11b and CD62L expression in patients undergoing regular hemodialysis. The effects of hemodialysis membranes were also studied in in vitro conditions after coincubating them with differentiated HL-60 cells. ROS production was measured using chemiluminometric and flow cytometric methods. Expression of CD11b, CD62L and mitochondrial membrane potential were detected by monoclonal antibodies and by the JC-1 fluorescent probe, respectively. Depressed ROS production was observed in patients already before dialysis. Further decrease in ROS production and an increase in CD11b expression were observed especially in patients after hemophan hemodialysis. Decreased ROS production and increased CD11b expression were observed also after incubation of HL-60 cells with hemophan membranes. Mitochondrial membrane potential dropped only after incubating cells with hemophan membranes proving its more serious adverse effects in comparison with the polysulfone membrane. In conclusion, deleterious effects of hemodialysis on the metabolic activity of phagocytes were proved. Combining chemiluminescent and flow cytometric methods for the detection of ROS production and determining mitochondrial membrane potential can be useful tools for the analysis of material biocompatibility.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of uremia and dialysis modality on mononuclear cell apoptosis.

The aim of this study was to evaluate the effect of both uremia itself and hemodialysis (HD) membranes on the induction of apoptosis. Four groups of subjects were evaluated: 21 nondialyzed (Non-D) patients, 10 continuous ambulatory peritoneal dialysis (CAPD) patients, and 53 HD patients who were on hemophan, cuprophan, cellulose acetate, AN69, and polysulfone; control subjects were nine healthy...

متن کامل

Advances in Polysulfone-Based Membranes for Hemodialysis

The polysulfone-based membrane has been used in hemodialysis (HD) and it is continuously developed to maintain its sustainability on the subject of biocompatibility. During the polysulfone-based membrane development, several parameters should be considered to improve the membrane performances, such as excellent biocompatibility, appropriate ultrafiltration rate, and effective clearance of the t...

متن کامل

نقش انواع فیلتر در میزان هیپوکسمی بیماران همودیالیزی

Introduction: One of the main complications of hemodialysis in patients with chronic renal failure is hypoxemia which is related to several factors including the type of filter. The aim of this study was to evaluate the hypoxemia levels in patients undergoing hemodialysis with focus on the type of filter. Methods: In a crossover clinical trial, 29 patients from emodialysis ward of Fatemieh hos...

متن کامل

In vitro study of r-hirudin permeability through membranes of different haemodialysers.

BACKGROUND After introducing the specific thrombin inhibitor recombinant hirudin (r-hirudin) into clinical practice in cases of heparin-induced thrombocytopenia (HIT, type II) the possibility of its use as an anticoagulant during haemodialysis treatment in HIT II patients is being discussed more frequently. On the one hand, the efficient, safe and routine use of r-hirudin during haemodialyses, ...

متن کامل

Thrombocytopenia in the Setting of Hemodialysis Using Biocompatible Membranes

Thrombocytopenia is a known potential side effect of hemodialysis, however, it is rarely seen in patients who undergo hemodialysis using biocompatible membranes. This case demonstrates hemodialysis-associated thrombocytopenia with use of biocompatible dialysis membranes that expose blood directly to polysulfone. The thrombocytopenia resolved in this patient when the dialysis membrane was change...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • General physiology and biophysics

دوره 21 4  شماره 

صفحات  -

تاریخ انتشار 2002