Study of precorneal tear film thickness and structure by interferometry and confocal microscopy.

نویسندگان

  • J I Prydal
  • F W Campbell
چکیده

Past measurements of precorneal tear film thickness in rabbits and humans gave values of 4-7 microns. These have been the accepted values. However, measurements presented in this report are much higher. Earlier techniques may have changed film thickness or not have fully included the layer containing mucus. Little is known about the mucus component. Thickness was measured in freshly killed animals of 10 species using two independent optical techniques. Coherent light was reflected from eyes and thickness was determined from spacing of interference fringes. Clear images of tissue structure were obtained with confocal microscopy, the tear film was visually identified, and thickness measured. Measurements by the two methods were closely correlated in each animal. No film was detected in trout or carp. In other species, thickness ranged from 9 microns in frogs to 15 microns in gerbils. Values are significantly larger than earlier estimates. Film thickness in three living rabbits was not significantly different from that measured shortly after death. There was no variation in thickness at five positions across the cornea in three species. Mucus content of rat tear film was examined by measuring thinning after application of 4, 8, and 20% (weight/volume) acetylcysteine, a mucolytic agent. Thickness was considerably reduced compared to controls, and the film almost completely removed by the highest concentration. The authors propose that the film is largely composed of mucus, not free aqueous solution. Our methods include such layers, and measurements are correspondingly larger than earlier ones.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of human precorneal tear film thickness and structure using laser interferometry.

The authors previously found that measurements of precorneal tear film thickness in animals, using laser interferometry and confocal microscopy, were larger than earlier estimates. They proposed that this occurred because optical methods did not disturb film structure and measured full thickness, including mucus. In the present study, tear film thickness was measured in humans. Coherent light w...

متن کامل

Structure and composition of rat precorneal tear film. A study by an in vivo cryofixation.

PURPOSE To visualize the in vivo structure and to investigate the composition of rat precorneal tear film. METHODS An in vivo cryofixation with freeze substitution method of electron microscopy was used for the study. For light and transmission electron microscopy, a small amount of aluminum powder was used as a tracer spread on the corneal surface. The eyeballs were immediately and quickly f...

متن کامل

Precorneal and pre- and postlens tear film thickness measured indirectly with optical coherence tomography.

PURPOSE To demonstrate the feasibility of indirectly measuring the precorneal tear film thickness and pre- and postlens tear film (PLTF) thickness using optical coherence tomography (OCT). METHODS Central corneal thickness (C(1)) which includes the tear film (T) of both eyes of 40 non-contact lens wearers was measured using OCT after calibration. The mean age of the 40 subjects was 31.2 +/- 9...

متن کامل

Tear film interferometry and corneal surface roughness.

PURPOSE Previous studies of optical interference from the whole thickness of the precorneal tear film showed much lower contrast than from the pre-contact lens tear film. It is hypothesized that the recorded low contrast is related to roughness of the corneal surface compared with the smooth contact lens surface. This hypothesis is tested, and characteristics of this roughness are studied. ME...

متن کامل

A novel method for pachymetry mapping of human precorneal tear film using Pentacam with fluorescein.

PURPOSE To report a novel method for pachymetry mapping of human precorneal tear film using Pentacam. METHODS Precorneal tear film is routinely undetected by Pentacam but could be well visualized with the aid of fluorescein. Twenty patients with dry eye and 20 age-matched control subjects with normal eyes were enrolled in this prospective study. The right eye of each subject was scanned once ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 33 6  شماره 

صفحات  -

تاریخ انتشار 1992