Minimally Invasive Plate Osteosynthesis for Open Fractures of the Proximal Tibia

نویسندگان

  • Joon-Woo Kim
  • Chang-Wug Oh
  • Won-Ju Jung
  • Ji-Soo Kim
چکیده

BACKGROUND Relatively few studies have addressed plate osteosynthesis for open proximal tibial fractures by now. The purpose of this study was to assess the results of minimally invasive plate osteosynthesis (MIPO) for open fractures of the proximal tibia. METHODS Thirty-four patients with an open proximal tibial fracture were treated by MIPO. Thirty of these, who followed for over 1 year, constituted the subject of this retrospective study. According to the AO Foundation and Orthopaedic Trauma Association (AO-OTA) classification, there were 3 patients of type 41-C, 6 of type 42-A, 8 of type 42-B, and 13 of type 42-C. In terms of the Gustilo and Anderson's open fracture grading system, 11 patients were of grade I, 6 were of grade II, and 13 were of grade III (III-A, 6; III-B, 6; III-C, 1). After thorough debridement and wound cleansing, when necessary, a soft tissue flap was placed. Primary MIPO (simultaneous plate fixation with soft tissue procedures) was performed in 18 patients, and staged MIPO (temporary external fixation followed by soft tissue procedures and subsequent conversion to plate fixation after soft tissue healing) was performed in 12 patients. Results were assessed according to the achievement and time to union, complications (including infections), and function of the knee joint using Knee Society scores. Statistical analysis was performed to identify factors influencing results. RESULTS Primary union was achieved by 24 of the 30 study subjects. Early bone grafting was performed in 6 cases with a massive initial bone defect expected to result in non-union. No patient had malalignment greater than 10°. The mean Knee Society score was 88.7 at final follow-up visits, 23 patients achieved an excellent result, and 7 a good result. There were 3 superficial and 5 deep infections, but none required early implant removal. Functional results were similar for primary and staged MIPO (p = 0.113). Fracture pattern (p = 0.089) and open fracture grade (p = 0.079) were not found to influence the results. CONCLUSIONS If soft tissue coverage is adequately performed, MIPO could be regarded as an acceptable method for the treatment of open proximal tibial fracture.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effectiveness of Minimally Invasive Plate Osteosynthesis (MIPO) on Comminuted Tibial or Femoral Fractures

Background: Comminuted fractures happen frequently due to traumas. Fixation without opening the fracture site,known as minimally invasive plate osteosynthesis (MIPO), has recently become prevalent. This study has beendesigned to assess the outcomes of this treatment for tibial and femoral comminuted fractures.Methods: A total of 60 patients with comminuted femoral or tibial fractures were opera...

متن کامل

Minimally Invasive Plate Osteosynthesis (MIPO) for Proximal and Distal Fractures of The Tibia: A Biological Approach

Introduction: The treatment of fractures of proximal and distal tibia is challenging, because of the limited soft tissue envelope and poor vascularity. The best treatment remains controversial and it depends on the fracture morphology, displacement and comminution. Treatment options vary from closed reduction and cast to open reduction and internal fixation with plate. Open reduction and intern...

متن کامل

Minimally Invasive Plate Osteosynthesis with Locking Compression Plate for Distal Diametaphyseal Tibia Fracture

Distal diametaphyseal tibia fracture though requires operative treatment is difficult to manage. Conventional osteosynthesis is not suitable because distal tibia is subcutaneous bone with poor vascularity. Closed reduction and minimally invasive plate osteosynthesis (MIPO) with locking compression plate (LCP) has emerged as an alternative treatment option because it respects biology of distal t...

متن کامل

Comparative study of intramedullary interlocking nailing and minimally invasive percutaneous plate osteosynthesis (MIPO) in extra articular distal tibial fracture

Introduction: Tibia is one of the most commonly fractured long bone of the body. Distal tibia fractures are primarily located within a square based on the width of the distal tibia. Treatment of distal tibia fracture is challenging because of its unique anatomical characteristics of subcutaneous location with precarious blood supply and proximity to the ankle joint. Minimally invasive plate ost...

متن کامل

Tibial Tuberosity Avulsion Fracture and Open Proximal Tibial Fracture in an Adult

A displaced tibial tuberosity avulsion fracture associated with an open extra-articular proximal tibial diaphyseal fracture is an uncommon fracture pattern. This case report describes the successful management of such a fracture pattern in a 45-year old male using an open reduction and lag screw fixation of the tuberosity with a minimally invasive reduction and plate fixation of the proximal ti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2012