Dynamic Buffer Capacity in Acid–Base Systems
نویسندگان
چکیده
The generalized concept of 'dynamic' buffer capacity βV is related to electrolytic systems of different complexity where acid-base equilibria are involved. The resulting formulas are presented in a uniform and consistent form. The detailed calculations are related to two Britton-Robinson buffers, taken as examples.
منابع مشابه
Evaluation of the SEAOC/UBC97 Provisions for the Tall Base-Isolated Structures
The base isolation systems are among the passive control devices that have been used over the last three decades to limit the seismic-induced response of structures. In this regard, the Uniform Building Code provisions (UBC) has incorporated a special section for the seismic design of base isolated structures since its 1991 edition. Due to the importance of the behavior of these structures unde...
متن کاملEvaluation of the SEAOC/UBC97 Provisions for the Tall Base-Isolated Structures
The base isolation systems are among the passive control devices that have been used over the last three decades to limit the seismic-induced response of structures. In this regard, the Uniform Building Code provisions (UBC) has incorporated a special section for the seismic design of base isolated structures since its 1991 edition. Due to the importance of the behavior of these structures unde...
متن کاملThe remarkable similarity between the acid-base properties of ISFETs and proteins and the consequences for the design of ISFET biosensors
Studying the acid-base properties of protein molecules led us to reconsider the operational mechanism of ISFETs. Based on the site-dissociation model, applied to the amphoteric metal oxide gate materials used in ISFETs, the sensitivity of ISFETs is described in terms of the intrinsic buffer capacity of the oxide surface,/3s, and the electrical surface capacitance, Cs. The ISFET sensitivity towa...
متن کاملThe Role of Histidine-Containing Compounds on the Buffering Capacity of Muscle
A buffer is defined as a compound that in small concentrations can impart a resistance to large pH changes. Common buffers contain two substances, a conjugate base and a conjugate acid. There are acidic buffers that contain a weak acid and the salt of a weak acid (the conjugate base) and basic buffers that contain a weak base and the salt of a weak base (the conjugate acid). The combination of ...
متن کاملDynamic Load Carrying Capacity of Mobile-Base Flexible-Link Manipulators: Feedback Linearization Control Approach
This paper focuses on the effects of closed- control on the calculation of the dynamic load carrying capacity (DLCC) for mobile-base flexible-link manipulators. In previously proposed methods in the literature of DLCC calculation in flexible robots, an open-loop control scheme is assumed, whereas in reality, robot control is achieved via closed loop approaches which could render the calculated ...
متن کامل