Sutures and Aeos ePTFE Monofilament
نویسندگان
چکیده
منابع مشابه
Off pump implantation of artificial chordae to correct mitral regurgitation – early results
Methods This data is part of multi-center, nonrandomized, prospective Transapical Artificial Chordae Tendinae [TACT] trial. 13 patients with severe mitral regurgitation caused by isolated posterior mitral valve leaflet prolapse, were included in the study. The operation was done through left anterolateral thoracotomy on a beating heart. With TEE guidance, the NeoChord DS1000 was introduced into...
متن کاملRecurrent mitral regurgitation due to ruptured ePTFE neochordae after mitral valve repair by the loop technique: a report of case.
Mitral valve (MV) repair with expanded polytetrafluoroethylene (ePTFE) sutures has proven to simple, versatile, and durable technique for the treatment of mitral valve regurgitation (MR). The ePTFE is known for its strong resistance to tension, and is judged to be unbreakable under physiological condition. The loop technique using premeasured ePTFE neochordae was employed from August 2005 for 2...
متن کاملAcute mitral regurgitation due to ruptured ePTFE neo-chordae.
Chordal replacement with expanded polytetrafluoroethylene (ePTFE) sutures has proven to be a simple, versatile, and durable technique for the treatment of prolapsed cusps causing mitral valve regurgitation. ePTFE is known for its strong resistance to tension, and is judged to be unbreakable under physiological conditions. Herein are reported two cases of rupture of synthetic chordae tendineae; ...
متن کاملComparison of E. coli Infiltration between New Synthetic Absorbable Sutures
Purpose: The proper selection of suture is very important to minimize infection after gastrointestinal anastomosis and closure, which is one of the causes of postoperative complications such as leakage and stricture, etc, in the surgical field. Thus this study focuses on which suture can reduce bacterial infection after surgical operation by comparing in vitro microbial infiltration rates of th...
متن کاملMechanical Properties of Polyglycolide-trimethylene Carbonate and Polydioxanone Monofilament Sutures in Vivo Used for Flexor Tendon Repair
INTRODUCTION Braided polyester suture materials have been commonly used for flexor tendon repair in the clinical setting. However, knotted braided polyester lost approximately 50% of its tensile strength according to a study by Trail et al.(1) Accordingly, 4 or 5 throws are needed to prevent slippage for a secure knot, which may result in stitch granuloma. The use of absorbable sutures avoids p...
متن کامل