Assessment of the Performance of a Ventilated Window Coupled with a Heat Recovery Unit through the Co-Heating Test
نویسندگان
چکیده
The aim of the article is to describe the results of an experimental campaign based on the assessment of a heat recovery unit coupled with a dynamic window. Two fully monitored and calibrated outdoor test cells are used, in order to evaluate the energy performance and the related thermal comfort. The former presents a traditional window with double-glazing, aluminum frame and indoor blind and a centrifugal extractor for the air circulation. The latter is equipped with a dynamic window with ventilated and blinded double-glazing provided with a heat exchanger. The connection of the dynamic window and heat recovery unit provides different actions: heat recovery; heat transfer reduction; pre-heating before the exchanger. Different operating configurations allowed the trends of the dynamic system to be assessed in different seasons in terms of energy saving, thermal comfort behavior and energy efficiency. The results showed an overall lower consumption of the innovative system, both in winter and summer, with 20% and 15% energy saving, respectively. In general, the dynamic system provided the best comfort conditions, even if it involves a worse behavior than expected, in the summer season.
منابع مشابه
Prediction of Noise Transmission Loss and Acoustic Comfort Assessment of a Ventilated Window using Statistical Energy Analysis
In this paper, a novel analytical method was developed based on statistical energy analysis framework to evaluate sound transmission loss through ventilated windows. The proposed method was compared to numerical and analytical models available in the literature. Results showed the success and advantage of the proposed model in predicting the acoustic performance of the ventilated window and the...
متن کاملEnergy efficiency in a building complex through seasonal storage of thermal energy in a confined aquifer
Confined aquifers are formations surrounded by impermeable layers called cap rocks and bed rocks. These aquifers are suitable for the seasonal storage of thermal energy. A confined aquifer was designed to meet the cooling and heating energy needs of a residential building complex located in Tehran, Iran. The annual cooling and heating energy needs of the buildings were estimated to be 8.7...
متن کاملارزیابی عملکرد تلفیق آبشیرینکن چنداثرۀ تقطیری با تراکم بخار (MED-TVC) در یک سیستم تولید همزمان برق، حرارت و سرما
In the present study, performance analysis of a multi effect distillation with thermo vapor compressor (MED-TVC) desalination system coupled to a combined cooling, heating and power (CCHP) system with gas turbine prime mover has been carried out to cogeneration of cooling, heating, power and potable water. The system incorporates air compressor, combustion chamber, gas turbine, triple pressure ...
متن کاملExergy Analysis of an Air Dehumidification System Equipped with Mixing Box and Heat Exchanger Heat Recovery Units
Exergy analysis emboldens in cases that all the inefficiencies and bottlenecks to improve energy systems are to be addressed. In this study, a novel vapor compression air dehumidifier integrated with an auxiliary heat exchanger in series arrangement with the main condenser in order to mitigate the reheat coil, and an extra mixing box to recover the ventilated air heat has been introduced. A com...
متن کاملFree convection in a 3D chamber with local cooling and heating
This paper modeled heating air of a room through examining free convection in a 3D chamber. The chamber had cold and hot sources with Tc and Th temperatures, respectively. Its other walls were adiabatic. This study aimed at predicting effect of temperature difference, displacement of hot and cold sources and their aspect ratio on flow field, temperature and heat transfer rate. To conduct the st...
متن کامل