Variability in patients with glaucomatous visual field damage is reduced using size V stimuli.
نویسندگان
چکیده
PURPOSE To test the hypothesis that variability of conventional automated perimetry can be reduced using size V stimuli for patients with glaucomatous visual field damage. METHODS Ten patients with glaucoma and five age-matched control volunteers were tested with the Humphrey Field Analyzer program 24-2 or 30-2, after which the method of constant stimuli was used to measure frequency-of-seeing curves. This was done by controlling the perimeter with a custom program run by a personal computer. At two widely separated visual field locations on the program 24-2 or 30-2 grid, stimuli were presented in 2 dB intervals to at least 10 dB on either side of the estimated program 24-2 or 30-2 threshold. This protocol was performed for each of three stimulus sizes (Goldmann sizes I, III, and V). For the patients with glaucoma, one test location was chosen in an area of normal visual field sensitivity, the other in an area of 10 to 20 dB loss. Control subjects were tested at the (3 degrees, 3 degrees) and (-21 degrees, -9 degrees) test locations. Fifteen repetitions were performed at each intensity. RESULTS Repeated measures analysis of variance showed that variability, as measured by the standard deviation of the cumulative Gaussian function of the fitted frequency-of-seeing curves, was lowest at the abnormal sensitivity test location in the subjects with glaucoma using a size V stimulus. Differences between the results from the V to III and V to I stimuli were statistically significant (size V = 2.9 dB, III = 10.1 dB, I = 10.1 dB). The same trend in estimated standard deviations was present in tests of the area of normal sensitivity (size V = 1.1 dB, III = 1.7 dB, I = 2.0 dB) in subjects with glaucoma and for the control subjects' peripheral test locations, but not for the central location. The smaller reduction in variability between estimated standard deviations of the size I and size III stimuli was not statistically significant at any test location. CONCLUSIONS Use of size V stimuli in conventional automated perimetry reduces variability in tests of moderately damaged and normal sensitivity test locations in subjects with glaucoma.
منابع مشابه
Investigating the effects of glaucomatous (POAG) damage on the mVEP parameters
Introduction: Glaucoma is considered as a major cause of irreversible vision loss, worldwide. Glaucoma includes a diverse ophthalmopathies characterized by attenuating the neural and connective tissue segments and eventually progression of specific patterns of visual dysfunction. Currently, perimetry is known as the most accurate diagnostic method in glaucoma and its follow up...
متن کاملChoice of Stimulus Range and Size Can Reduce Test-Retest Variability in Glaucomatous Visual Field Defects.
PURPOSE To develop guidelines for engineering perimetric stimuli to reduce test-retest variability in glaucomatous defects. METHODS Perimetric testing was performed on one eye for 62 patients with glaucoma and 41 age-similar controls on size III and frequency-doubling perimetry and three custom tests with Gaussian blob and Gabor sinusoid stimuli. Stimulus range was controlled by values for ce...
متن کاملThe Effective Dynamic Ranges for Glaucomatous Visual Field Progression With Standard Automated Perimetry and Stimulus Sizes III and V
Purpose It has been shown that threshold estimates below approximately 20 dB have little effect on the ability to detect visual field progression in glaucoma. We aimed to compare stimulus size V to stimulus size III, in areas of visual damage, to confirm these findings by using (1) a different dataset, (2) different techniques of progression analysis, and (3) an analysis to evaluate the effect ...
متن کاملPerimetric sensitivity and response variability in glaucoma with single-stimulus automated perimetry and multiple-stimulus perimetry with verbal feedback.
PURPOSE To measure perimetric sensitivity and response variability of glaucomatous patients with single-stimulus automated perimetry (SSAP) and multiple-stimulus perimetry (MSP) with verbal feedback. METHODS Frequency-of-seeing (FOS) data were collected from the same four visual field locations (normal and reduced sensitivity) in one eye of 10 glaucoma patients, using SSAP and MSP. The SSAP t...
متن کاملComparison of Swedish interactive threshold algorithm and full threshold algorithm for glaucomatous visual field loss.
PURPOSE To compare the prevalence of visual field loss, the sensitivity distribution, and the size and depth of glaucomatous visual field defects using the standard full threshold (FT) and the Swedish interactive threshold algorithm (SITA) standard (SS) procedures in patients with early or suspected glaucoma. METHODS Automated perimetry findings were retrospectively evaluated in 53 patients (...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 38 2 شماره
صفحات -
تاریخ انتشار 1997