The effects of passive humidifier dead space on respiratory variables in paralyzed and spontaneously breathing patients.
نویسندگان
چکیده
BACKGROUND Passive humidifiers have gained acceptance in the intensive care unit because of their low cost, simple operation, and elimination of condensate from the breathing circuit. However, the additional dead space of these devices may adversely affect respiratory function in certain patients. This study evaluates the effects of passive humidifier dead space on respiratory function. METHODS Two groups of patients were studied. The first group consisted of patients recovering from acute lung injury and breathing spontaneously on pressure support ventilation. The second group consisted of patients who were receiving controlled mechanical ventilation and were chemically paralyzed following operative procedures. All patients used 3 humidification devices in random order for one hour each. The devices were a heated humidifier (HH), a hygroscopic heat and moisture exchanger (HHME) with a dead space of 28 mL, and a heat and moisture exchanger (HME) with a dead space of 90 mL. During each measurement period the following were recorded: tidal volume, minute volume, respiratory frequency, oxygen consumption, carbon dioxide production, ratio of dead space volume to tidal volume (VD/VT), and blood gases. In the second group, intrinsic positive end-expiratory pressure was also measured. RESULTS Addition of either of the passive humidifiers was associated with increased VD/VT. In spontaneously breathing patients, VD/VT increased from 59 +/- 13 (HH) to 62 +/- 13 (HHME) to 68 +/- 11% (HME) (p < 0.05). In these patients, constant alveolar ventilation was maintained as a result of increased respiratory frequency, from 22.1 +/- 6.6 breaths/min (HH) to 24.5 +/- 6.9 breaths/min (HHME) to 27.7 +/- 7.4 breaths/min (HME) (p < 0.05), and increased minute volume, from 9.1 +/- 3.5 L/min (HH) to 9.9 +/- 3.6 L/min (HHME) to 11.7 +/- 4.2 L/min (HME) (p < 0.05). There were no changes in blood gases or carbon dioxide production. In the paralyzed patient group, VD/VT increased from 54 +/- 12% (HH) to 56 +/- 10% (HHME) to 59 +/- 11% (HME) (p < 0.05) and arterial partial pressure of carbon dioxide (PaCO2) increased from 43.2 +/- 8.5 mm Hg (HH) to 43.9 +/- 8.7 mm Hg (HHME) to 46.8 +/- 11 mm Hg (HME) (p < 0.05). There were no changes in respiratory frequency, tidal volume, minute volume, carbon dioxide production, or intrinsic positive end-expiratory pressure. DISCUSSION These findings suggest that use of passive humidifiers with increased dead space is associated with increased VD/VT. In spontaneously breathing patients this is associated with an increase in respiratory rate and minute volume to maintain constant alveolar ventilation. In paralyzed patients this is associated with a small but statistically significant increase in PaCO2. CONCLUSION Clinicians should be aware that each type of passive humidifier has inherent dead space characteristics. Passive humidifiers with high dead space may negatively impact the respiratory function of spontaneously breathing patients or carbon dioxide retention in paralyzed patients. When choosing a passive humidifier, the device with the smallest dead space, but which meets the desired moisture output requirements, should be selected.
منابع مشابه
HY POXIA AND I TS INFLUEN CES ON THE CARDIOVASCULAR AND RESPIRATORY SYSTEMS OF SPONTANEOUSLY BREATHING CATS
Effects of acute systemic hypoxia on the cardiovascular system (CYS) and respiration of spontaneously breathing cats were studied in two conditions. 1): Hypoxic air (6-8% 02 in N2) was given to the animal to induce systemic hypoxia for 20 minutes. Hyperventilation at this condition lowered arterial C02 tension (PaC02 hypocapnia). 2): In the second run, induction of hypocapnia was prevented ...
متن کاملPhysiologic impact of closed-system endotracheal suctioning in spontaneously breathing patients receiving mechanical ventilation.
BACKGROUND Endotracheal suctioning is required but can have adverse effects, and could affect cardiorespiratory variables that are used to predict whether the patient is ready for extubation. METHODS In a prospective cohort study in a university hospital's medical intensive care unit, we measured the impact of closed-system suctioning on cardiopulmonary variables in spontaneously breathing pa...
متن کاملEquipment review: Mechanical effects of heat-moisture exchangers in ventilated patients
Although they represent a valuable alternative to heated humidifiers, artificial noses have unfavourable mechanical effects. Most important of these is the increase in dead space, with consequent increase in the ventilation requirement. Also, artificial noses increase the inspiratory and expiratory resistance of the apparatus, and may mildly increase intrinsic positive end-expiratory pressure. ...
متن کاملDelivery of molecular versus particulate water in spontaneously breathing tracheotomized patients.
BACKGROUND Adequate humidification of inspired gas with active or passive humidifiers is a standard of care for tracheotomized patients. In this study, a comparison is made between the tracheal climate after tracheobronchial humidification either with molecular water (via a vaporizing humidifier) or particulate water (via spray) in spontaneously breathing tracheotomized patients. METHODS We p...
متن کاملInterfaces and humidification for noninvasive mechanical ventilation.
During noninvasive ventilation (NIV) for acute respiratory failure, the patient's comfort may be less important than the efficacy of the treatment. However, mask fit and care are needed to prevent skin damage and air leaks that can dramatically reduce patient tolerance and the efficacy of NIV. Choice of interface is a major determinant of NIV success or failure. The number and types of NIV inte...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Respiratory care
دوره 45 3 شماره
صفحات -
تاریخ انتشار 2000