Low-flow anaesthesia.

نویسنده

  • J A Baum
چکیده

Although many anaesthesia machines are equipped with circle rebreathing systems, inhalational anaesthesia remains frequently performed using relatively high fresh-gas flows. The major advantages of rebreathing techniques can be achieved only if the fresh-gas flow is reduced to 1 l.min-1 or less. Although there are potential risks associated with low-flow anaesthesia, modern anaesthesia machines meet all the technical requirements for the safe use of low-flow techniques if they are used in conjunction with equipment for monitoring inhaled and exhaled gas concentrations; these monitors are already increasingly available and, in the near future, are likely to become an obligatory safety standard in many countries. For both economic and ecological reasons, the use of new inhalational anaesthetics, with low tissue solubility and low anaesthetic potency, can be justified only if the efficiency of administration is optimised by using low-flow anaesthetic techniques.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bispectral index and cerebral oximetry in low-flow and high-flow rate anaesthesia during laparoscopic cholecystectomy – a randomized controlled trial

INTRODUCTION The need to reduce pollution emissions in the operating room and to reduce treatment costs motivates more frequent use of general anaesthesia with a small or minimal fresh gas flow rate. Nevertheless, the reduction of the delivery of fresh gases should not influence the quality and safety of the anaesthesia. MATERIAL AND METHODS A total of 105 elective laparoscopic cholecystectom...

متن کامل

Cost Analysis of Three Techniques of Administering Sevoflurane

Background. This study aimed to evaluate and compare total cost of sevoflurane and propofol for 1.0 MAC-hour of anaesthesia, employing three anaesthetic techniques. Methods. Adult patients scheduled for surgical procedures under general anaesthesia anticipated to last approximately an hour were randomized into three groups (n = 15 each), to receive anaesthesia using one of the following techniq...

متن کامل

The accuracy of the respirometer and ventigrator.

The respirometer under-reads at low flow rates and over-reads at high flow rates, but during anaesthesia, the respiratory waveform and the nature of the respired gas combine' to minimize the low error which would otherwise result from hypoventilation. Over-reading is to be expected during hyperventilation of the anaesthetized patient. The error will always exaggerate a departure from normality....

متن کامل

Fuzzy logic control of inspired isoflurane and oxygen concentrations using minimal flow anaesthesia.

In order to evaluate the performance of feedback fuzzy logic control of inspired oxygen and isoflurane concentrations, we studied 30 patients undergoing discectomy for lumbar (n = 26) or cervical (n = 4) disc herniation. Patients were allocated random to one of two groups: a standard group (n = 15) with low flow anaesthesia (1.2-1.3 litre min-1) and manual control of gas concentrations; and a f...

متن کامل

An Adaptive Gpc Approach to Low-flow Anaesthesia

An adaptive method is developed to control the end-tidal isoflurane concentration using a low-flow method. The isoflurane concentration is calculated based on measurements of the end-tidal isoflurane concentration and mean arterial pressure (MAP) using a modelbased multivariable GPC algorithm. The control design allows explicit handling of input and output constrains, accommodates model uncerta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European journal of anaesthesiology

دوره 13 5  شماره 

صفحات  -

تاریخ انتشار 1995