A collaborative European study of personal inhalable aerosol sampler performance.
نویسندگان
چکیده
Following the adoption of new international sampling conventions for inhalable, thoracic and respirable aerosol fractions, a working group of Comité Européen de Normalisation (CEN) drafted a standard for the performance of workplace aerosol sampling instruments. The present study was set up to verify the experimental, statistical and mathematical procedures recommended in the draft performance standard and to check that they could be applied to inhalable aerosol samplers. This was achieved by applying the tests to eight types of personal inhalable aerosol sampler commonly used for workplace monitoring throughout Europe. The study led to recommendations for revising the CEN draft standard, in order to simplify the tests and reduce their cost. However, some further work will be needed to develop simpler test facilities and methods. Several of the samplers tested were found to perform adequately with respect to the inhalable sampling convention, at least over a limited range of typical workplace conditions. In general the samplers were found to perform best in low external wind speeds, which are the test conditions thought to be closest to those normally found in indoor workplaces. The practical implementation of the CEN aerosol sampling conventions requires decisions on which sampling instruments to use, estimation of the likely impact that changing sampling methods could have on apparent exposures, and adjustment where necessary of exposure limit values. The sampler performance data obtained in this project were affected by large experimental errors, but are nevertheless a useful input to decisions on how to incorporate the CEN inhalable sampling convention into regulation, guidance and occupational hygiene practice.
منابع مشابه
Performance of personal inhalable aerosol samplers in very slowly moving air when facing the aerosol source.
While personal aerosol samplers have been characterized primarily based on wind tunnel tests conducted at relatively high wind speeds, modern indoor occupational environments are usually represented by very slow moving air. Recent surveys suggest that elevated levels of occupational exposure to inhalable airborne particles are typically observed when the worker, operating in the vicinity of the...
متن کاملLaboratory study of selected personal inhalable aerosol samplers.
Assessment of inhalable dust exposure requires reliable sampling methods in order to measure airborne inhalable particles' concentrations. Many inhalable aerosol samplers can be used but their performances widely vary and remain unknown in some cases. The sampling performance of inhalable samplers is strongly dependent on particle size and ambient air velocity. Five inhalable aerosol samplers h...
متن کاملWorker exposures to inhalable and total aerosol during nickel alloy production.
This paper describes a study that was carried out at a North American nickel alloy production facility to compare the levels of personal exposures to inhalable and total nickel-containing aerosols. It is part of a large body of work aimed at assessing the impact of introducing new personal sampling instrumentation with performance consistent with the latest criteria proposed by the Internationa...
متن کاملExposure to metalworking fluid aerosols and determinants of exposure.
Metalworking fluid (MWF) aerosols are associated with respiratory disorders including asthma and hypersensitivity pneumonitis. The aims of this study were to describe exposure to inhalable MWF aerosols and volatile compounds in machine shops, to estimate the influence of important determinants of exposure and to compare different sampling techniques for MWF aerosols. Personal full-shift air sam...
متن کاملResearch Papers Involving the Tsi Respicontm Sampler
Six inhalable aerosol samplers were evaluated experimentally as area samplers using monodisperse solid particles with aerodynamic diameters ranging from 5 to 68 mm. Sampler performance and inside particle loss at two test wind speeds (0.55 and 1.1 m/sec) and three wind orientations (0, 90, and 180 degrees) were investigated. The six inhalable aerosol samplers tested were a RESPICONTM sampler, a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Annals of occupational hygiene
دوره 41 2 شماره
صفحات -
تاریخ انتشار 1997