Real-time visualization of thrombus formation at the interface between connectors and tubes in medical devices by using optical coherence tomography
نویسندگان
چکیده
BACKGROUND Blood-contacting devices have contributed to improving the treatment of patients. However, thrombus formation at the interface between a connector and tube is still a potential source of thrombus-related complications that induce stroke or myocardial infarction. We aimed to develop a non-blood-contacting real-time method for visualizing thrombus formation, and to experimentally investigate the time-dependent phenomenon of thrombus formation at the interface between a connector and a tube in a medical device. METHODS AND FINDINGS An optical coherence tomography device with a center wavelength of 1330 nm was used to visualize thrombus formation during porcine blood circulation for 50 min in a closed 50-mL circulation system isolated from ambient air. The thrombus formation sites at the interface between a tube and connector were visualized. The area of the thrombus formation at the interface between the inlet of the connector and the tube was found to be 0.012 ± 0.011 mm2. Conversely, at the interface between the outlet of the connector and the tube, the area was found to be 0.637 ± 0.306 mm2. Thus, significantly larger amounts of thrombus were formed at the outlet interface (p < 0.01). The thrombus formation area at the outlet interface increased over time. Conversely, the area of thrombus formation showed repeated increasing and decreasing behavior at the inlet interface. Flow visualization with particle image velocimetry showed the presence of a flow separated area in the minimal flow phase at the inlet interface and a large recirculating slow flow region at the outlet interface in the minimal flow phase. These data suggested that the recirculating stagnant flow region contributed to thrombus growth. CONCLUSIONS The method presented here was effective in quantitatively assessing time-dependent phenomena of thrombus formation at the connector-tube interface. The method may contribute to the assessment of thrombogenicity of a novel design of connector.
منابع مشابه
Experimental Visualization of Labyrinthine Structure with Optical Coherence Tomography
Introduction:Visualization of inner ear structures is a valuable strategy for researchers and clinicians working on hearing pathologies. Optical coherence tomography (OCT) is a high-resolution imaging technology which may be used for the visualization of tissues. In this experimental study we aimed to evaluate inner ear anatomy in well-prepared human labyrinthine bones.Materials and Methods:Thr...
متن کاملComparison of Choroidal Thickness in Psoriasis and Control Groups Using Optical Coherence Tomography
Background and Objective: One of the most common extracutaneous complications in psoriasis patients is ocular complications, which is controversial concerning its effect on choroidal thickness. This study aimed to compare the psoriasis patients with healthy individuals in terms of the thickness of the choroidal layer using the optical coherence tomography technique. Materials and Methods: In t...
متن کاملDevelopment of an Advanced Optical Coherence Tomography System for Radiation Dosimetry
Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...
متن کاملOptical Coherence Tomography and Corpus Callosum Index in Cognitive Assessment of Multiple Sclerosis Patients
Background: Multiple Sclerosis (MS) is a neurodegenerative disease of central nervous system. Different approaches have been developed to study MS progression and cognitive dysfunction as the major symptom of the disease. The current study compared Optical Coherence Tomography (OCT) and Corpus Callosum Index (CCI) for the early evaluation of cognitive dysfunction in MS patients. Objectives: T...
متن کاملCorrelation between Visual Acuity and Optical Coherence Tomography-Measured Retinal Thickness in Diabetic Macular Edema
Background and Objective: Diabetic macular edema (DME) is one of the common complications of diabetes which significantly accounts for preventable visual impairment and blindness. Central macular thickness (CMT) is a feature found in DME patients. This study aims to determine the relationship between optical coherence tomography (OCT)-measured CMT and visual acuity (VA) in patients with DME bef...
متن کامل