Assessment of the effectiveness of a ventilator associated pneumonia prevention bundle that contains endotracheal tube with subglottic drainage and cuff pressure monitorization.

نویسندگان

  • Ozlem Akdogan
  • Yasemin Ersoy
  • Ciğdem Kuzucu
  • Ender Gedik
  • Turkan Togal
  • Funda Yetkin
چکیده

The effectiveness of prevention bundles on the occurrence and mortality of ventilator associated pneumonia (VAP) was evaluated in many studies. However, the effectiveness of endotracheal tube with subglottic secretion drainage (ETT-SD) and cuff pressure monitorization in VAP bundles have not been adequately assessed. In this study, we aimed to evaluate the effectiveness of VAP bundle containing ETT-SD and cuff pressure monitorization. This was a prospective, controlled study that was carried out between March 2011 and April 2012 including intubated patients. The study was conducted at the Anesthesiology Intensive Care Unit 1 and 2 (10 beds each) in a 898-bed university hospital. Occurrence of VAP and compliance with the parameters of the VAP prevention bundles were assessed daily. Patients intubated with the standard endotracheal tube were recruited as controls, mainly in the first six months of the study as ETT-SD and cuff pressure monometer had not yet been implemented. In the second term, patients intubated with ETT-SD were included as cases. Occurrence of VAP, mortality, and compliance with VAP prevention bundles were monitored. A total of 133 patients, 37 cases and 96 controls were recruited. VAP incidence declined from 40.82 to 22.16 per 1000 ventilator days among controls and cases, respectively (p<005). On average, VAP occurred 17.33±21.09 days in the case group and 10.43±7.83 days in the control group (p=0.04). However, mortality of cases and controls at the 14th and 30th days was not different. VAP prevention bundles including the utilization of ETT-SD, monitoring cuff pressure, and oral care with chlorhexidine were efficient in reducing the rate of VAP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Continuous endotracheal tube cuff pressure control system protects against ventilator-associated pneumonia

INTRODUCTION The use of a system for continuous control of endotracheal tube cuff pressure reduced the incidence of ventilator-associated pneumonia (VAP) in one randomized controlled trial (RCT) with 112 patients but not in another RCT with 142 patients. In several guidelines on the prevention of VAP, the use of a system for continuous or intermittent control of endotracheal cuff pressure is no...

متن کامل

An in vitro microbiological study comparing eight endotracheal tubes and their ability to prevent microaspiration

Introduction The major cause of ventilator-associated pneumonia (VAP) is the aspiration of bacteria-laden subglottic secretions past the cuff of the endotracheal tube (ETT) [1]. When the ETT cuff is inflated to the correct wall pressure, excess cuff material folds and causes involutions thereby forming channels, which allow leakage of subglottic secretions to the lungs [2]. Now, new ETT cuffs h...

متن کامل

Impact of supra-cuff suction on ventilator-associated pneumonia prevention

Critically ill patients are intubated or tracheostomized because, in most cases, these individuals require invasive mechanical ventilation. The cannulae that are used include the cuff, which can act as a reservoir for oropharyngeal secretions, predisposing to ventilator-associated pneumonia. Studies have revealed that the suction of subglottic secretions through the dorsal suction lumen above t...

متن کامل

How to avoid microaspiration? A key element for the prevention of ventilator-associated pneumonia in intubated ICU patients

Microaspiration of subglottic secretions through channels formed by folds in high volume-low pressure poly-vinyl chloride cuffs of endotracheal tubes is considered a significant pathogenic mechanism of ventilator-associated pneumonia (VAP). Therefore a series of prevention measures target the avoidance of microaspiration. However, although some of these can minimize microaspiration, benefits in...

متن کامل

Effect of intermittent subglottic secretion drainage on ventilator-associated pneumonia: A clinical trial

BACKGROUND Secretions contaminated with oral, nasal, and gastric bacteria accumulate in the subglottic space, above the endotracheal tube cuff. If these secretions are aspirated into lower airways, the intubated patient will be susceptible to ventilator-associated pneumonia (VAP). The aim of this study was to investigate the effect of inspiratory pause maneuver for intermittent subglottic secre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Brazilian journal of infectious diseases : an official publication of the Brazilian Society of Infectious Diseases

دوره 21 3  شماره 

صفحات  -

تاریخ انتشار 2017