Low dose capsule based 13c-urea breath test compared with the conventional 13c-urea breath test and invasive tests.

نویسندگان

  • Rejane Mattar
  • Cibele Aparecida Villares
  • Priscila Faria França Marostegam
  • Cleuber Esteves Chaves
  • Vanusa Barbosa Pinto
  • Flair José Carrilho
چکیده

CONTEXT One of the limitations of 13C-urea breath test for Helicobacter pylori infection diagnosis in Brazil is the substrate acquisition in capsule presentation. OBJECTIVES The purpose of this study was to evaluate a capsule-based 13C-urea, manipulated by the Pharmacy Division, for the clinical practice. METHODS Fifty patients underwent the conventional and the capsule breath test. Samples were collected at the baseline and after 10, 20 and 30 minutes of 13C-urea ingestion. Urease and histology were used as gold standard in 83 patients. RESULTS In a total of 50 patients, 17 were positive with the conventional 13C-urea (75 mg) breath test at 10, 20 and 30 minutes. When these patients repeated breath test with capsule (50 mg), 17 were positive at 20 minutes and 15 at 10 and 30 minutes. The relative sensitivity of 13C-urea with capsule was 100% at 20 minutes and 88.24% at 10 and at 30 minutes. The relative specificity was 100% at all time intervals. Among 83 patients that underwent capsule breath test and endoscopy the capsule breath test presented 100% of sensitivity and specificity. CONCLUSIONS Capsule based breath test with 50 mg 13C-urea at twenty minutes was found highly sensitive and specific for the clinical setting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The 13C-urea breath test to detect Helicobacter pylori infection: a validated simple methodology with 50 mg 13C-urea.

BACKGROUND Several modifications of the 13C-urea breath test have been published. For reasons of cost efficiency and practicability, the urea dose and measurement duration should be reduced while still maintaining excellent diagnostic accuracy. AIMS To establish a validated simple protocol for the urea breath test with 50 mg 13C-urea and to compare this protocol with the conventional urea bre...

متن کامل

Masking of 13C urea breath test by proton pump inhibitors is dependent on type of medication: comparison between omeprazole, pantoprazole, lansoprazole and esomeprazole.

BACKGROUND The need to withhold acid suppression therapy while awaiting urea breath test results is a common clinical problem in symptomatic patients. It is unclear at present if the dose or type of proton pump inhibitor or the type of test meal govern the apparent masking effect of proton pump inhibitors on the urea breath test. AIM To prospectively evaluate Helicobacter pylori detection rat...

متن کامل

The 13C urea breath test in the diagnosis of Helicobacter pylori infection.

The urea breath test (UBT) is one of the most important non-invasive methods for detecting Helicobacter pylori infection. The test exploits the hydrolysis of orally administered urea by the enzyme urease, which H pylori produces in large quantities. Urea is hydrolysed to ammonia and carbon dioxide, which diffuses into the blood and is excreted by the lungs. Isotopically labelled CO2 can be dete...

متن کامل

Evaluation of the Ez-HBT Helicobacter blood test to establish Helicobacter pylori eradication.

BACKGROUND The urea blood test (Ez-HBT) has been shown to compare favourably with the urea breath test in the diagnosis of active Helicobacter pylori infection. AIM To examine the performance characteristics of the Ez-HBT Helicobacter blood test in establishing success or failure of therapy in H. pylori-infected adults using the 13C urea breath test as the reference method. METHODS 13C urea...

متن کامل

[Validation of a simplified 13C-urea breath test method for the diagnosis of Helicobacter pylori infection].

OBJECTIVE To validate a simplified 13C-urea breath test (13C-UBT) method for the diagnosis of H. pylori infection. MATERIAL AND METHODS Patients referred for gastrointestinal endoscopy and biopsy were included, and a 13C-UBT was performed after a 6-hour fast. Breath samples were collected in 10 ml glass tubes before and 30 min after the simultaneous administration of 50 mg of 13C-urea and 2 g...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arquivos de gastroenterologia

دوره 51 2  شماره 

صفحات  -

تاریخ انتشار 2014