Design and operation of a protection system for transformers with superconducting windings

نویسنده

  • F. van Overbeeke
چکیده

Power transformers with superconducting windings need a protection system to prevent damage to the low-loss superconducting winding by an abnormally high current. The generally accepted protection technique which uses auxiliary coils has been analysed using a network representation. The current distribution between main and auxiliary coil is expressed in terms of geometrical parameters. Experimental data on current transfer and main coil recovery in a test transformer are presented and a method of obtaining a very low auxiliary coil current is suggested.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Internal Protection of Transformer Windings Against Transeint Surges Using ZnO Varistors

Power system overvoltages due to switching, lightning and other disturbances are the main problem for designers of the power transformers. Once some frequencies of the incoming surges match with some of the natural frequencies of transformer winding, the resonance phenomenon is expected in transformer winding. The resonant overvoltages may destroy the insulation between turns and cause to insul...

متن کامل

Internal Protection of Transformer Windings Against Transeint Surges Using ZnO Varistors

Power system overvoltages due to switching, lightning and other disturbances are the main problem for designers of the power transformers. Once some frequencies of the incoming surges match with some of the natural frequencies of transformer winding, the resonance phenomenon is expected in transformer winding. The resonant overvoltages may destroy the insulation between turns and cause to insul...

متن کامل

Mathematical Proof for the Minimized Stray Fields in Transformers Using Auxiliary Windings Based on State Equations for Evaluation of FEM Results

Stray magnetic field is one of the main issues in design of transformers, since it causes non-ideal behavior of transformers. One of the techniques is usually adopted to mitigate the unwanted stray magnetic field is the use of auxiliary windings creating a magnetic field opposite to the incident one giving rise to the reduction of the total magnetic fields. This paper presents a new mathematica...

متن کامل

Characterization of Power Transformer Electromagnetic Forces Affected by Winding Faults

Electromagnetic forces in power transformer windings are produced by interaction between the leakage fluxes and current passing them. Since the leakage flux distribution along the windings height is in two axial and radial directions, so the electromagnetic forces have two components, radial and axial. There is a risk that a large electromagnetic force due to the short circuit or inrush current...

متن کامل

Transformer Inrush Current and Related Challenges

Energizing of large power transformers is considered a critical event in the operation of an electric power system. When a transformer is energized by the grid or utility, it takes very high value current known as inrush current, the typical value of this current could be ten times. This inrush causes many problems like mechanical stress on transformer & harmonics injection to generator winding...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002