Design and operation of a protection system for transformers with superconducting windings
نویسنده
چکیده
Power transformers with superconducting windings need a protection system to prevent damage to the low-loss superconducting winding by an abnormally high current. The generally accepted protection technique which uses auxiliary coils has been analysed using a network representation. The current distribution between main and auxiliary coil is expressed in terms of geometrical parameters. Experimental data on current transfer and main coil recovery in a test transformer are presented and a method of obtaining a very low auxiliary coil current is suggested.
منابع مشابه
Internal Protection of Transformer Windings Against Transeint Surges Using ZnO Varistors
Power system overvoltages due to switching, lightning and other disturbances are the main problem for designers of the power transformers. Once some frequencies of the incoming surges match with some of the natural frequencies of transformer winding, the resonance phenomenon is expected in transformer winding. The resonant overvoltages may destroy the insulation between turns and cause to insul...
متن کاملInternal Protection of Transformer Windings Against Transeint Surges Using ZnO Varistors
Power system overvoltages due to switching, lightning and other disturbances are the main problem for designers of the power transformers. Once some frequencies of the incoming surges match with some of the natural frequencies of transformer winding, the resonance phenomenon is expected in transformer winding. The resonant overvoltages may destroy the insulation between turns and cause to insul...
متن کاملMathematical Proof for the Minimized Stray Fields in Transformers Using Auxiliary Windings Based on State Equations for Evaluation of FEM Results
Stray magnetic field is one of the main issues in design of transformers, since it causes non-ideal behavior of transformers. One of the techniques is usually adopted to mitigate the unwanted stray magnetic field is the use of auxiliary windings creating a magnetic field opposite to the incident one giving rise to the reduction of the total magnetic fields. This paper presents a new mathematica...
متن کاملCharacterization of Power Transformer Electromagnetic Forces Affected by Winding Faults
Electromagnetic forces in power transformer windings are produced by interaction between the leakage fluxes and current passing them. Since the leakage flux distribution along the windings height is in two axial and radial directions, so the electromagnetic forces have two components, radial and axial. There is a risk that a large electromagnetic force due to the short circuit or inrush current...
متن کاملTransformer Inrush Current and Related Challenges
Energizing of large power transformers is considered a critical event in the operation of an electric power system. When a transformer is energized by the grid or utility, it takes very high value current known as inrush current, the typical value of this current could be ten times. This inrush causes many problems like mechanical stress on transformer & harmonics injection to generator winding...
متن کامل