Right Ventricular Pacing and Sensing Function in High Posterior Septal and Apical Lead Placement in Cardiac Resynchronization Therapy
نویسندگان
چکیده
BACKGROUND The conventional right ventricular (RV) lead position in cardiac resynchronization therapy pacemakers (CRT-P) is the RV apex (RV-A). Little is known about electrophysiological stability and associated complications of pacing leads in RV high posterior septal (RV-HS) position in CRT-P. METHODS Two hundred and thirty-five consecutive CRT-P patients were included from 1999-2010. Pacing thresholds at 0.5ms and 2.5V, sensing electrograms and lead impedances were measured at implant and repeated 1,3,6,12,18 and 24 months after CRT-P. Electrophysiological measurements of leads located in RV-A and RV-HS were analyzed retrospectively. Bipolar RV leads were used, including high impedance leads, passive fixation and active fixation. RESULTS RV pacing leads were implanted in RV-A (n=79) and RV-HS (n=156). Average RV pacing thresholds from CRT implant procedure to 24-month follow-up at 0.5ms were 0.77±0.69V in RV-A and 0.71±0.35V in RV-HS (P=0.31), and at 2.5V were 0.06±0.08ms in RV-A and 0.07±0.05ms in RV-HS (P=0.12). Average RV electrogram amplitudes from baseline to 24 months after CRT were 15.3±6.9mV in RV-A and 12.1±6.0mV in RV-HS (P=0.55). Average RV impedances during follow-up were 850±286Ω in RV-A and 618±147Ω in RV-HS (P=0.57). Similar RV lead revisions between RV-A and RV-HS were observed after 2-year follow-up (P=0.55). CONCLUSION The RV-HS lead position demonstrated stable and acceptable long-term pacing and sensing function, with rates of complications comparable to conventional RV-A lead position in CRT. The RV-HS lead position is feasible in CRT-P.
منابع مشابه
Right Apical, Biventricular and Right High Septal Ventricular Pacing: A Comparison of Procedural Burden and Long Term Electrical Performance
Background/Aims: It has previously been shown that permanent right ventricular (RV) apical pacing may lead to worsening of cardiac function due to associated electrical and mechanical dyssynchrony. Cardiac resynchronization therapy (CRT) or high septal RV pacing could be beneficial to prevent patients from these negative effects. Methods/Results: In this single center clinical study 164 patient...
متن کاملMaximal electric separation-guided placement of right ventricular lead improves responders in cardiac resynchronization defibrillator therapy.
BACKGROUND Cardiac resynchronization therapy is widely used for the treatment of heart failure. Recent data suggest that electric separation during left ventricular pacing varies within the right ventricle (RV). We hypothesized that placement of the RV lead guided by maximal electric separation (MES) would improve response to cardiac resynchronization therapy compared with standard apical place...
متن کاملThe effects of right ventricular apical pacing on ventricular function and dyssynchrony implications for therapy.
Cardiac pacing is the only effective treatment for patients with sick sinus syndrome and atrioventricular conduction disorders. In cardiac pacing, the endocardial pacing lead is typically positioned at the right ventricular (RV) apex. At the same time, there is increasing indirect evidence, derived from large pacing mode selection trials and observational studies, that conventional RV apical pa...
متن کاملCardiac Resynchronization Therapy in Patients with Ebstein's Anomaly.
Ebstein's anomaly is a rare congenital heart disease characterized by apical displacement of the septal and posterior tricuspid valve leaflets. It is often complicated with left ventricular (LV) dysfunction as well as right-sided abnormalities. On the other hand, in the presence of LV dysfunction, right ventricular pacing is likely to aggravate the diseased LV function, which is termed pacemake...
متن کاملTargeted left ventricular endocardial pacing using a steerable introducing guide catheter and active fixation pacing lead.
AIMS Cardiac resynchronization therapy via the coronary sinus (CS) is not always possible. Left ventricular (LV) endocardial lead placement is a potential alternative. The purpose of this study was to assess the feasibility of endocardial LV pacing using a steerable lead introducer and active fixation polyurethane lead. METHODS AND RESULTS Endocardial LV lead placement was attempted in nine p...
متن کامل