Right Versus Left Prong Nasal Cannula Flow Delivery and the Effects of Nasal Cycling on Inspired F(IO2) in an Adult Anatomic Model.
نویسندگان
چکیده
BACKGROUND Nasal cycling may present negative consequences for oxygen-dependent patients using a nasal cannula. This study investigates the effects of nasal cycling on the delivered F(IO2) via nasal cannula in an anatomic model following a baseline study comparing right and left prong nasal cannula oxygen flow delivery. METHODS Flow from right and left nasal cannula prongs were measured simultaneously using thermal mass flow meters while delivering 0.5-6-L/min oxygen for 5 nasal cannulas from different manufacturers. An adult mannikin head with an anatomically correct upper airway was connected to a QuickLung Breather test lung. Nasal cannula-delivered F(IO2) was recorded using a polarographic oxygen analyzer with naris occlusion simulated by inserting a 5.0 endotracheal tube into the naris and inflating the endotracheal tube cuff. Data were recorded with both nares open, for right naris occluded and left naris patent, and for left naris occluded and right naris patent at 0.5-6 L/min. RESULTS A paired t test demonstrated statistical differences between right and left nasal cannula prong oxygen flows (P < .01). Multivariate analysis of variance demonstrated no significant differences in nasal cannula prong flow between nasal cannula manufacturers. Repeated measures analysis of variance demonstrated significant differences for measured inspired F(IO2) (P < .01) when alternating nares were occluded and patent. The Bonferroni post hoc test showed significant differences for measured F(IO2) between patent nares and right naris patent-left naris occluded (P < .01) and between patent nares and left naris patent-right naris occluded (P < .01). Measured F(IO2) decreased by as much as 0.1 when one naris was occluded. CONCLUSIONS Oxygen delivery by nasal cannula may be inefficient in the presence of the nasal cycle. Delivered nasal cannula oxygen concentrations decreased when bilateral nasal patency changed to unilateral nasal patency. Although statistically different, nasal cannula prong oxygen flow may not be clinically important across the full range of flows.
منابع مشابه
Effects of Breathing Pattern on Oxygen Delivery Via a Nasal or Pharyngeal Cannula.
BACKGROUND During sedation for upper gastrointestinal endoscopy, oxygen delivery via a nasal cannula is often necessary. However, the influences of the oxygen delivery route and breathing pattern on the F(IO2) have not been thoroughly investigated. The aim of this simulation study was to investigate the difference in the F(IO2) with a pharyngeal cannula versus nasal cannula during high- or low-...
متن کاملHeated Humidified High-Flow Nasal Cannula Versus Nasal Continuous Positive Airway Pressure for the Facilitation of Extubation in Preterm Neonates with Respiratory Distress
Background: Heated humidified high-flow nasal cannula (HHHFNC) is gaining popularity as an alternative to nasal continuous positive airway pressure (nCPAP) therapy in the management of preterm neonates with respiratory distress due to ease of administration and patient comfort. However, limited evidence is available addressing its risks and benefits. To study the efficacy and safety of HHHFNC i...
متن کاملActive anterior rhinomanometric (AAR) evaluation of nasal airway resistance in normal Iranian sample
Abstract: Background: The most important and complex phenomenon of respiratory function of the nose is related to different nasal anatomy. The differences in facial anatomic structure between different races may also be reflected in nasal resistance and airflow. Caucasians has different facial anatomic structure which is the reflection of intranasal resistance or consequence of airflow. The...
متن کاملEffect of the anatomic reservoir on low-flow oxygen delivery via nasal cannula: constant flow versus pulse flow with portable oxygen concentrator.
BACKGROUND The F(IO(2)) for a nasal cannula with constant flow (CF) depends on the anatomic reservoir (AR), which is affected by changes in frequency and end-expiratory flow. Conversely, pulse flow (PF) devices do not require the AR. The purpose of this study was to compare the F(IO(2)) delivered by a nasal cannula supplied by CF via oxygen tank with that delivered by PF delivered via portable ...
متن کاملEffective inspired oxygen concentration measured via transtracheal and oral gas analysis.
BACKGROUND The fraction of inspired oxygen (F(IO(2))) is quoted for different oxygen delivery systems, but variations in inspiratory flow and tidal volume make precise measurement difficult. We developed a reliable method of measuring the effective F(IO(2)) in patients receiving supplemental oxygen. METHODS Ten subjects with chronic hypoxemia breathed through a mouthpiece with a sampling prob...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Respiratory care
دوره 61 4 شماره
صفحات -
تاریخ انتشار 2016