Ring current asymmetry from global simulations using a high-resolution electric field model

نویسندگان

  • V. K. Jordanova
  • Y. Dotan
چکیده

[1] We study ring current evolution during the 10 January 1997 geomagnetic storm, comparing results from two inner magnetospheric convection electric field models: (1) the Kp-dependent Volland-Stern (V-S) model and (2) the high spatial and temporal resolution assimilative mapping of ionospheric electrodynamics (AMIE) model, coupled with our global ring current model. We have added a penetration electric field (driven by partial ring current closure in the ionosphere) to the AMIE model which improves the agreement at low L shells with Polar/EFI measurements, and we mapped the modified AMIE convection electric potentials (MACEP) to the equatorial plane. Both V-S and MACEP convection models predict a very asymmetric local time distribution of ring current energy density during the main and early recovery phase of the storm. However, the peak of the medium energy ions is located during the main phase near midnight when the MACEP model is used, while it is located near dusk using V-S. In both models the energy density peak is located near dusk during the early recovery, and the ring current becomes symmetric during the late recovery phase. Ring current injection is larger, penetrating to lower L shells, and the Dst index is significantly better reproduced using MACEP rather than using V-S model. We compare model results with Polar data and find reasonably good agreement with both models at larger L shells and near dawn. The enhanced storm time distributions at low L shells near dusk are better modeled with MACEP. Electromagnetic ion cyclotron (EMIC) waves are predominantly excited near Dst minimum, have larger wave gain, and cause stronger ion precipitation using the MACEP model. In this case the calculated ion precipitation patterns exhibit features consistent with storm time Polar/IPS observations and show enhancements within the plasmaspheric bulge and along the duskside plasmapause. In the dusk to midnight sector at L > 5, however, there seems to be a need to include the effect of an additional scattering process during highly active conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gyri-precise head model of transcranial direct current stimulation: improved spatial focality using a ring electrode versus conventional rectangular pad.

The spatial resolution of conventional transcranial direct current stimulation (tDCS) is considered to be relatively diffuse owing to skull dispersion. However, we show that electric fields may be clustered at distinct gyri/sulci sites because of details in tissue architecture/conductivity, notably cerebrospinal fluid (CSF). We calculated the cortical electric field/current density magnitude in...

متن کامل

The effects of dynamic ionospheric outflow on the ring current

[1] The importance of ionospheric O on the development of the storm time ring current is recognized but not well understood. The addition of this outflow in global MHD models has the potential to change the magnetic field configuration, particle densities and temperatures, and the convection electric field. This makes including heavy ion outflow in ring current simulations difficult, as this ad...

متن کامل

Efficient Analysis of Plasmonic circuits using Differential Global Surface Impedance (DGSI) Model

Differential global surface impedance (DGSI) model, a rigorous approach, has been applied to the analysis of three dimensional plasmonic circuits. This model gives a global relation between the tangential electric field and the equivalent surface electric current on the boundary of an object. This approach helps one bring the unknowns to the boundary surface of an object and so avoid volumetric...

متن کامل

Analysis of Grading Ring Design Parameters and Heat Sink Numbers Effect on Voltage Distribution and Leakage Current in Metal Oxide Surge Arrester

Metal oxide surge arresters (ZNO) are used widely in power system to protect equipments from over voltages. Non uniform potential distribution leads to the depressed service life and low safe reliability, so grading ring is applied on HV surge arrester order to uniform the electric field distribution. One of the problems of arresters is leakage current in power frequency that different paramet...

متن کامل

Effects of Disc Insulator Type and Corona Ring on Electric Field and Voltage Distribution over 230-kV Insulator String by Numerical Method

Insulator strings with several material and profiles are very common in overhead transmission lines. However, the electric field and voltage distribution of insulator string is uneven which may easily lead to corona, insulators’ surface deterioration and even flashover. So the calculation of the electric field and voltage distribution along them is a very important factor in the operation time....