On-Site Preparation of Tc-99m Albumin for Clinical Application

نویسندگان

  • YUH-FENG WANG
  • MEI-HUA CHUANG
چکیده

WANG, Y.F., CHUANG, M.H., CHIU, J.S., CHAM, T.M. and CHUNG, M.I. On-Site Preparation of Technetium-99m Labeled Human Serum Albumin for Clinical Application. Tohoku J. Exp. Med., 2007, 211 (4), 379-385 ── Technetium-99m labeled human serum albumin (Tc-99m HSA) is an important radiopharmaceutical for clinical applications, such as cardiac function tests or protein-losing gastroenteropathy assessment. However, because of transfusion-induced infectious diseases, the safety of serum products is a serious concern. In this context, serum products acquired from patients themselves are the most ideal tracer. However, the development of rapid separation and easy clinical labeling methods is not yet well established. Under such situation, products from the same ethnic group or country are now recommended by the World Health Organization as an alternative preparation. This article describes the on-site preparation of Tc-99m HSA from locally supplied serum products. Different formulations were prepared and the labeling efficiency and stability were examined. Radio-labeling efficiencies were more than 90% in all preparation protocols, except for one that omitted the stannous solution. The most cost-effective protocol contained HSA 0.1 mg, treated with stannous fluoride 0.2 mg, and mixed with Tc99m pertechnetate 30 mCi. A biodistribution study was performed in rats using a gamma camera immediately after intravenous administration of radiolabeled HSA. Tissue/organ uptake was obtained by measuring the radioactivity in organs after sacrificing the rats at timed intervals. The biologic half-life was about 32 min, determined from sequential venous blood collections. These data indicate that our preparation of Tc-99m HSA is useful and potentially applicable clinically. In addition, this on-site preparation provides the possibility of labeling a patient’s own serum for subsequent clinical application. ──── Technetium-99m; albumin; radiopharmaceutical; infection; biodistribution © 2007 Tohoku University Medical Press

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of a freeze-dried radiopharmaceutical kit for dopamine transporters imaging

Introduction: 99mTc-TRODAT-1 is a promising new radiopharmaceutical with the potential for routine use as the radiopharmaceutical for dopamine transporters scintigraphy as far as its image quality and daily availability are concerned. Here we describe the development of a freeze-dried kit formulation based on the tricine exchange labeling approach for the preparation of this radiopha...

متن کامل

Tc-99m human serum albumin lymphoscintigraphy with SPECT/CT in chylothorax.

A 45-year old man who had refractory right chylothorax after esophagectomy for esophageal cancer underwent lymphoscintigraphy with Tc-99m human serum albumin. Focal abnormal uptake was seen in the mid abdomen on planar image 30 minutes after the tracer injection. SPECT/CT delineated the extent of the accumulation between the anastomotic site and the right pleural effusion area. SPECT/CT had a g...

متن کامل

Clinical Evaluation of a New 99mTc-MAA Kit for Lung Scanning

Lung scanning has been recognized as a clinically useful technique for portraying macroscopic pulmonary perfusion defects since it was first reported by Wagner in 1964 (1 ). A number of radiopharmaceuticals have been proposed to assess pulmonary perfusion. Although 1 3 1 I imposes many limitations as a radiotagging agent, the use of iodinated macroaggregated albumin (I-MAA) has received wide ac...

متن کامل

Preparation of human serum albumin microspheres (MSA) kit for lung imaging in Iran [Persian]

Radiolabeled Microspheres of human serum albumin (MSA) is of great importance in the analysis of regional lung perfusion. Preparation of MSA kit has been installed in our Division recently is carried out in two stages: 1. Production of albumin sphere particles with suitable sizes by using the spinning disk technique. 2. Formulation of MSA as a radiopharmacutical kit. So it can be labelled...

متن کامل

Imaging of Clot by 99mTc-HMPAO Labeled Platelet in Animal Model Induced Thrombosis

99mTc-HMPAO labeled platelet (LP) imaging may integrate thrombosis imaging into routine clinical procedures. In the current study, we assessed the feasibility of the use of 99mTc-HMPAO LP for imaging of small clots in an animal model. Thrombosis was induced by application of FeCl3 solution in the distal part of the inferior vena cava (IVC) of a 6100 g anesthetiz...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003