AbstractID: 8177 Title: A Clinical Example of the Helical Tomotherapy Thread Effect: Robustness Discussion

ثبت نشده
چکیده

ID: 8177 Title: A Clinical Example of the Helical Tomotherapy Thread Effect: Robustness Discussion Purpose: A previous study explained why pitches of 0.86/n, where n is an integer, will provide the best junctioning of a helically delivered and diverging beam. The previous treatment was theoretical and based on unmodulated examples. In this study, a clinically relevant case of a palliative lung treatment with arm blocking that was artificially extended in order to test limits, was used to test the 0.86/n pitches and explore a deeper understanding. Method and Materials: The thread effect ripples were measured in the middle of the PTV for a large number of sequential pitches on a TomoTherapy planning station for the situations of no arm blocking and for very large arm blocks that extend +/15cm in order to create a very modulated sinogram. A typical 2.5cm beam was used. The patient was anonymous. Results: The 0.86/n pitches were observed to be the best choices in both cases for minimizing the thread effect. Conclusion: By using a simplified analysis, one can easily appreciate that the reason for this robustness was that the complexity of the sinogram modulations were periodic in phase with the gantry rotation, and the 1/n factor is the result of an integral over n gantry rotations. Since most structures that cause such complexity are larger than the beam width times the pitch in length, most sinograms will be complex in this fashion, and the p=0.86/n relation is expected to be rather robust for most clinical situations. It is recommended that TomoTherapy treatments use the proper pitches of 0.86/n if there is no other reason not to.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

AbstractID: 3490 Title: Non-Tumor Integral Dose in Conformal, External Beam Radiation Therapy

ID: 3490 Title: Non-Tumor Integral Dose in Conformal, External Beam Radiation Therapy Purpose: To investigate the computed non-tumor integral dose (NTID) delivered during treatment of prostate cancer with intensity modulated radiotherapy (IMRT) compared to three-dimensional conformal radiotherapy (3DCRT). Low and highenergy photon treatments were also evaluated in this study, as was helical tom...

متن کامل

Intensity Modulated Arc Therapy: Technology and Clinical Implementation

ID: 10351 Title: Advances in arc therapy Intensity Modulated Arc Therapy: Technology and Clinical Implementation Cedric X. Yu University of Maryland School of Medicine AbstractID: 10351 Title: Advances in arc therapyID: 10351 Title: Advances in arc therapy Abstract Intensity modulated arc therapy (IMAT) was proposed by Yu as an alternative to Tomotherapy. Over more than a decade, many progresse...

متن کامل

The helical tomotherapy thread effect.

Inherent to helical tomotherapy is a dose variation pattern that manifests as a "ripple" (peak-to-trough relative to the average). This ripple is the result of helical beam junctioning, completely unique to helical tomotherapy. Pitch is defined as in helical CT, the couch travel distance for a complete gantry rotation relative to the axial beam width at the axis of rotation. Without scattering ...

متن کامل

AbstractID: 5462 Title: Advances in Co-60 based Tomotherapy Including Megavoltage CT

ID: 5462 Title: Advances in Co-60 based Tomotherapy Including Megavoltage CT Purpose: To evaluate the potential for Co-60 based tomotherapy including dose delivery and mega-voltage CT (MVCT). Tomotherapy is a rotational implementation of IMRT that provides highly conformal doses and patient setup verification using MVCT. Current tomotherapy is limited to linear accelerators. This poster present...

متن کامل

The evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy

Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008