An unusual presentation of catastrophic failure of hip arthroplasty with a thigh mass
نویسندگان
چکیده
In the advent of increasing demand for total hip arthroplasty, surveillance of these patients is imperative to identify potential complications requiring revision surgery. This is especially important in the young population, as revision is usually necessary during their lifetime. We present a case of a young female patient with a history of total hip arthroplasty 17 years prior, who presented with left hip pain and anterior thigh mass. The prosthetic hip had progressed to catastrophic failure with the cobalt-chrome femoral head having eroded through the polyethylene and acetabular socket. This was associated with significant metal debris and large fluid collection in the thigh. The patient required complex revision surgery but could have had a much lesser procedure with earlier intervention.
منابع مشابه
Fatal Cobalt Cardiomyopathy Following Revision Total Hip Arthroplasty – A Brief Report with Review of Literature
Ceramic bearing surfaces are being increasingly used in young patients undergoing total hip arthroplasty. However,failures have been reported including fractures even with the newer third generation ceramics. The recommendedtreatment for fracture of ceramic bearing surfaces is complete synovectomy and revision total hip arthroplasty.However, disappointing results have also bee...
متن کاملUnusual presentation of failed metal-on-metal total hip arthroplasty with features of neoplastic process
Metal-on-metal (MoM) total hip arthroplasty (THA) is associated with increased incidence of failure from metallosis, adverse tissue reactions, and the formation of pseudotumors. This case highlights a 53-year-old female with an enlarging painful thigh mass 12 years status post MoM THA. Radiographs and advanced imaging revealed an atypical mass with cortical bone destruction and spiculation, con...
متن کاملIncreased Risk of Heterotopic Ossification Following Revision Hip Arthroplasty for Periprosthetic Joint Infection
Purpose: To investigate whether surgery for PJI of the hip, the number of procedures and their duration contribute to risk of HO formation. Methods: 56 patients with hip PJI undergoing one-stage (10) or two-stage (46) exchange arthroplasty were matched to 112 patients undergoing revision arthroplasty for aseptic failure based on age, gender, body mass index (BMI), surgical approach (all direct...
متن کاملAn unusual presentation of mammary Paget’s disease with a 12-year duration and no palpable mass
Paget’s disease of the nipple is an unusual manifestation of breast cancer. Most cases of mammary Paget`s disease are associated with an invasive or in situ breast tumor, even with no mass observed in mammography imaging. Very rarely does Paget’s disease occur in the absence of any underlying neoplasia .Herein, we report an 82-year-old woman with an unusual presentation of mammary Paget’s disea...
متن کاملMigration of a Broken Steinman Pin into the Posterior Compartment of the Leg 12 Years after Total Hip Arthroplasty
This report is on a migration of a Steinman pin into the posterior com Department of the calf. It was used to fix a greater trochanteric osteotomy in a total hip arthroplasty. The puzzling note is how this metal piece passed through the anterolateral compartment of the thigh to the posterior compartment of the calf. Accord ing to our literature review, migration of fixation pins through the kne...
متن کامل