Analytical possibilities of total reflection X-ray spectrometry (TXRF) for trace selenium determination in soils.

نویسندگان

  • E Marguí
  • G H Floor
  • M Hidalgo
  • P Kregsamer
  • G Román-Ross
  • C Streli
  • I Queralt
چکیده

Selenium content of soils is an important issue due to the narrow range between the nutritious requirement and toxic effects upon Se exposure. However, its determination is challenging due to low concentrations within complex matrices that hamper the analysis in most spectroscopic techniques. In this study, we explored the possibilities of several analytical approaches combined with total reflection X-ray (TXRF) spectrometry for soil Se determinations. The direct analysis of a solid suspension using 20 mg of fine ground material (<50 μm) has a relatively high Se limit of detection (LOD) of 1 mg/kg (worldwide Se average in soils = 0.4 mg/kg) and is therefore only suitable for seleniferous soils. Several fast and simple analytical strategies were developed to decrease matrix effects and improve the LOD for Se determination in soil digests. On one hand, the application of a liquid-liquid extraction procedure using ethyl ether and the introduction of a Cr absorbent in the instrument configuration were carried out to avoid the associated problems on TXRF analysis of soil extracts due to the high Fe concentrations (∼700 mg/L). On the other hand, a dispersive liquid-liquid microextraction procedure (DLLME) before the TXRF analysis of the soil digest was also developed. The effects of various experimental parameters such as sample volume, effect of major elements present in the soil matrix (Fe), and Se concentration in the sample were investigated. The LOD using this analytical methodology (0.05 mg/kg of Se) was comparable to or lower than those obtained in previous works using other popular spectrometric techniques such as GFAAS, ICPMS, and AFS. The calculated Se concentration for JSAC-0411 ([Se] = 1.32 ± 0.27 mg/kg) using the combination of DLLME and TXRF ([Se] = 1.40 ± 0.23 mg/kg) was in agreement with the certified value.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Environmental trace-element analysis using a benchtop total reflection X-ray fluorescence spectrometer.

Total reflection X-ray fluorescence (TXRF) analysis is an established technique for trace-element analysis in various types of samples. Though expensive large-scale systems restricted the applications in the past, in this study the capability of a benchtop system for trace elemental analysis is reported. The suitability of this system for the mobile on-site analysis of heavy metal contaminated ...

متن کامل

Total Reflection X-ray Fluorescence Spectrometry for Characterization of Nuclear Materials

Total reflection X-Ray Fluorescence (TXRF) is a comparatively new technique of material characterization and trace element analysis. It is an advanced variant of Energy Dispersive X-ray Fluorescence (EDXRF) and is based on the principle of total reflection of X-rays when these radiations fall on a flat smooth surface at a grazing angle less than the critical angle of the sample support. The cri...

متن کامل

Analytical approaches for Hg determination in wastewater samples by means of total reflection X-ray fluorescence spectrometry.

At present, there is a considerable interest in Hg monitoring in wastewater samples due to its widespread occurrence and the high toxicity of most of its compounds. Hg determination in water samples by means of total reflection X-ray fluorescence spectrometry (TXRF) entails some difficulties due to the high vapor pressure and low boiling point of this element that produce evaporation and loss o...

متن کامل

Evaluation of the protein concentration in enzymes via determination of sulfur by total reflection X-ray fluorescence spectrometry limitations of the method

Ž . Total reflection X-ray fluorescence spectrometry TXRF offers many advantages for the identification of trace elements in biological samples like proteins, enzymes, tissues or plants. Because of difficult and time consuming isolations and cleaning procedures enzyme samples are often available in small amounts only. Using TXRF without any preliminary treatment, a ‘screening’ of such samples t...

متن کامل

Synchrotron radiation-induced total reflection X-ray fluorescence analysis

Synchrotron radiation-induced total reflection X-ray fluorescence (SR-TXRF) analysis is a high sensitive analytical technique that offers limits of detection in the femtogram range for most elements. Besides the analytical aspect, SR-TXRF is mainly used in combination with angle-dependent measurements and/or X-ray absorption near-edge structure (XANES) spectroscopy to gain additional informatio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 82 18  شماره 

صفحات  -

تاریخ انتشار 2010