Improving the specificity of R2′ to the deoxyhaemoglobin content of brain tissue: Prospective correction of macroscopic magnetic field gradients

نویسندگان

  • Nicholas P. Blockley
  • Alan J. Stone
چکیده

The reversible transverse relaxation rate, R2', is sensitive to the deoxyhaemoglobin content of brain tissue, enabling information about the oxygen extraction fraction to be obtained. However, R2' is also sensitive to macroscopic magnetic field gradients, particularly at air-tissue interfaces where a large susceptibility difference is present. It is important that this latter effect is minimised in order to produce meaningful estimates of blood oxygenation. Therefore, the aim of this study was to implement a technique to prospectively correct for the effect of susceptibility induced magnetic field gradients on R2' weighted data. This was achieved by combining the Gradient-Echo Slice Excitation Profile Imaging (GESEPI) technique with an Asymmetric Spin Echo (ASE) pulse sequence. The main advantages of this approach are (i) shorter acquisition times, since a separately acquired magnetic field map is not required and (ii) simpler analysis, since retrospective correction for the effects of magnetic field gradients in postprocessing is not required. In these experiments we show that with this newly developed technique it is possible to correct the majority of grey matter voxels for the expected distribution of through-slice magnetic field gradients to produce maps of R2' in a short scan duration.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mixed model phase evolution for correction of magnetic field inhomogeneity effects in 3D quantitative gradient echo-based MRI.

PURPOSE In 3D gradient echo magnetic resonance imaging (MRI), strong field gradients B0macro are visually observed at air/tissue interfaces. At low spatial resolution in particular, the respective field gradients lead to an apparent increase in intravoxel dephasing, and subsequently, to signal loss or inaccurate R2* estimates. If the strong field gradients are measured, their influence can be r...

متن کامل

Detection of Glioblastoma Multiforme Tumor in Magnetic Resonance Spectroscopy Based on Support Vector Machine

Introduction: The brain tumor is an abnormal growth of tissue in the brain, which is one of the most important challenges in neurology. Brain tumors have different types. Some brain tumors are benign and some brain tumors are cancerous and malignant. Glioblastoma Multiforme (GBM) is the most common and deadliest malignant brain tumor in adults. The average survival rate for peo...

متن کامل

Fast, high resolution T2* mapping using 3D MGE and 3D EPI, with 3D correction for macroscopic dephasing effects

Introduction: T2* relaxation reflects both non-reversible microscopic T2 processes and reversible T2' processes. Whilst T2' is influenced by intravoxel dephasing due to such clinically interesting, tissue-specific quantities as local iron concentration, its reliability in comparative and longitudinal studies is limited by the dephasing effect of static magnetic field gradients, which are domina...

متن کامل

Quantitative Comparison of SPM, FSL, and Brainsuite for Brain MR Image Segmentation

Background: Accurate brain tissue segmentation from magnetic resonance (MR) images is an important step in analysis of cerebral images. There are software packages which are used for brain segmentation. These packages usually contain a set of skull stripping, intensity non-uniformity (bias) correction and segmentation routines. Thus, assessment of the quality of the segmented gray matter (GM), ...

متن کامل

Comparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction

Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • NeuroImage

دوره 135  شماره 

صفحات  -

تاریخ انتشار 2016