Heparin or 0.9% sodium chloride to maintain central venous catheter patency: a randomized trial.
نویسندگان
چکیده
OBJECTIVE To compare heparin (3 mL, 10 units/mL) and 0.9% sodium chloride (NaCl, 10 mL) flush solutions with respect to central venous catheter lumen patency. DESIGN Single-center, randomized, open label trial. SETTING Medical intensive care unit and Surgical/Burn/Trauma intensive care unit at Barnes-Jewish Hospital, St. Louis, MO. PATIENTS Three hundred forty-one patients with multilumen central venous catheters. Patients with at least one lumen with a minimum of two flushes were included in the analysis. INTERVENTIONS Patients were randomly assigned within 12 hrs of central venous catheter insertion to receive either heparin or 0.9% sodium chloride flush. MEASUREMENTS AND MAIN RESULTS The primary outcome was lumen nonpatency. Secondary outcomes included the rates of loss of blood return, inability to infuse or flush through the lumen (flush failure), heparin-induced thrombocytopenia, and catheter-related blood stream infection. Assessment for patency was performed every 8 hrs in lumens without continuous infusions for the duration of catheter placement or discharge from intensive care unit. Three hundred twenty-six central venous catheters were studied yielding 709 lumens for analysis. The nonpatency rate was 3.8% in the heparin group (n = 314) and 6.3% in the 0.9% sodium chloride group (n = 395) (relative risk 1.66, 95% confidence interval 0.86-3.22, p = .136). The Kaplan-Meier analysis for time to first patency loss was not significantly different (log rank = 0.093) between groups. The rates of loss of blood return and flush failure were similar between the heparin and 0.9% sodium chloride groups. Pressure-injectable central venous catheters had significantly greater rates of nonpatency (10.6% vs. 4.3%, p = .001) and loss of blood return (37.0% vs. 18.8%, p <.001) compared to nonpressure-injectable catheters. The frequencies of heparin-induced thrombocytopenia and catheter-related blood stream infection were similar between groups. CONCLUSION 0.9% sodium chloride and heparin flushing solutions have similar rates of lumen nonpatency. Given potential safety concerns with the use of heparin, 0.9% sodium chloride may be the preferred flushing solution for short-term use central venous catheter maintenance.
منابع مشابه
ASHP therapeutic position statement on the institutional use of 0.9% sodium chloride injection to maintain patency of peripheral indwelling intermittent infusion devices.
0.9% Sodium chloride injection is a safe and effective indwelling solution for maintaining catheter patency of peripheral indwelling intermittent infusion devices (PIIIDs) in adults and children age one year or older. ASHP supports the use of 0.9% sodium chloride injection in preference to heparin-containing flush solutions (heparin flush) in the institutional setting, on the basis of clinical ...
متن کاملComparison of the Effects of Heparin and 0.9% Sodium Chloride Solutions in Maintenance of Patency of Central Venous Catheters
BACKGROUND Occlusion of central venous catheters is one of the limiting factors in using them. Heparinized saline solution is the standard solution used for keeping the catheters open. OBJECTIVES This study aimed to determine the effect of heparin saline solution and normal saline in maintenance of patency of central venous catheters. PATIENTS AND METHODS This double-blind study was perform...
متن کاملLocking solutions for hemodialysis catheters; heparin and citrate--a position paper by ASDIN.
There is wide variation in the use of solutions to "lock" or fill tunneled central venous catheters for dialysis. Some centers use undiluted heparin concentrations ranging from 1000 to 10,000 U/ml and other centers place from 1000 to 10,000 U per lumen. Based on available evidence, it appears that heparin 1000 U/ml, or 4% sodium citrate are suitable choices for lock solution to maintain patency...
متن کاملHeparinized and Saline Solutions in the Maintenance of Arterial and Central Venous Catheters After Cardiac Surgery
BACKGROUND Heparinized saline solution is used to prevent occlusion in the arterial catheters and central venous pressure monitoring catheters. Even at low dose, heparin administration can be associated with serious complications. Normal saline solution can maintain patency of arterial catheters and central venous pressure monitoring catheters. OBJECTIVES The current study aimed to compare th...
متن کاملHeparin versus 0.9% sodium chloride intermittent flushing for the prevention of occlusion in long term central venous catheters in infants and children.
BACKGROUND Guidelines and clinical practice for the prevention of complications associated with central venous catheters (CVC) around the world vary greatly. Most institutions recommend the use of heparin to prevent occlusion, however there is debate regarding the need for heparin and evidence to suggest 0.9% sodium chloride (normal saline) may be as effective. The use of heparin is not without...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Critical care medicine
دوره 40 6 شماره
صفحات -
تاریخ انتشار 2012