Imaging with unfocused regions of focused ultrasound beams.
نویسندگان
چکیده
This article gives an analytical, computational, and experimental treatment of the spatial resolution encoded in unfocused regions of focused ultrasound beams. This topic is important in diagnostic ultrasound since ultrasound array systems are limited to a single transmit focal point per acoustic transmission, hence there is a loss of spatial resolution away from the transmit focus, even with the use of dynamic receive focusing. It is demonstrated that the spatial bandwidth of a Gaussian-apodized beam is approximately constant with depth, which means that there is just as much encoded spatial resolution away from the transmit focus as there is in the focal region. The practical application of this principle is discussed, an algorithm for retrospectively focusing signals from unfocused regions of fixed-focus beams is presented, and a quantitative comparison between the authors' methods and dynamic-receive beamforming is provided.
منابع مشابه
High-resolution photoacoustic imaging with focused laser and ultrasonic beams.
We report a photoacoustic imager that utilizes a focused laser beam in combination with a 20 MHz ultrasound focusing transducer to obtain micron-resolution tissue images over a long working distance. The imager is based on a ring transducer that combines ultrasonic and laser beams collinearly and confocally in a monolithic element. The combination of focused laser beam and short pulse irradiati...
متن کاملPET and MRI-guided focused ultrasound surgery for hypoxic-tissue ablation combined with radiotherapy in solid tumors
Background: The rationale was to develop an ablation approach to destroy regions of tumor resistant to radiation and thus reduce the time required for whole tumor ablation, while improving overall tumor control after radiotherapy. Materials and Methods: The system is composed of a micro positron emission tomography (mPET), 7T magnetic resonance imaging (MRI), and a customized MRI-compatible foc...
متن کاملTemperature distributions in tissues during local hyperthermia by stationary or steered beams of unfocused or focused ultrasound.
Temperature distributions resulting from insonation with stationary or steered beams of unfocused or focused ultrasound were measured in tissue-equivalent phantom, beef muscle in vitro, dog muscle mass, and transplanted murine tumours in vivo. Arrays of 4 to 6 thermocouples stepped through the volume of interest under computer control were used to measure the steady-state temperatures at 600 to...
متن کاملHigh Frequency Backscatter Measurements of Bovine Tissues with Unfocused and Focused Transducers
In order to improve resolution of ultrasonic imaging, high frequency scanners which are employed in the range 20 MHZ to 50 MHz are needed. As a result, it is critical to obtain data on ultrasonic scattering and attenuation in this frequency range. At these high frequencies, it is not feasible to make scattering measurements with unfocused transducers; therefore focused transducers are needed. U...
متن کاملPhotoacoustic Tomography Imaging of the Adult Zebrafish by Using Unfocused and Focused High-Frequency Ultrasound Transducers
The zebrafish model provides an essential platform for the study of human diseases or disorders due to the possession of about 87% homologous genes with human. However, it is still very challenging to noninvasively visualize the structure and function of adult zebrafish based on available optical imaging techniques. In this study, photoacoustic tomography (PAT) was utilized for high-resolution ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of the Acoustical Society of America
دوره 121 3 شماره
صفحات -
تاریخ انتشار 2007