Evolution of X‐ray machine quality control acceptance indices
نویسندگان
چکیده
The quality assurance (QA) of radiographic images based on the operating conditions of X-ray equipment is essential for good image quality, accurate medical diagnostics and for the prevention of health professionals and patients to unnecessary doses of ionizing radiation. This paper presents a historical analysis of 1,635 Quality Assurance Technical Reports of Health Institutions in the state of São Paulo, Brazil, over a seven-year period. Based on acceptable limits for variations between nominal and measured parameters as the variable to determine the quality of X-ray equipment operating conditions, a significant improvement was found in the percentage of acceptance of the overall parameters described in the QA technical reports over this period. As expected, we found a strong concentration in the categories of conventional and portable X-ray equipment, which represent 72% and 84%, respectively, of the total number of equipments. A mechanical parameter such as half-value layer (HVL), which is important not only for image quality but also for radiation protection, showed significant improvements. Again, only 58% of portable X-ray equipment showed HVL values recommended for 80 kVp (above 2.3 mm Al), a percentage that improved to 76% in 2006. With regard to mammographers, which are newer machines, all the analyzed systems presented acceptable HVL values. Conventional X-ray machines showed an increase of this conformity index from 89% in 2000 to 94% in 2006. All this improvement was attributed to the continuous and extensive enforcement of Regulation Act 453 in the state of São Paulo. The improvement in equipment quality control standards is expected to result in the improvement of diagnostic quality, as well as in the reduction of exam repetitions, and thereby reducing the patient's exposure to radiation.
منابع مشابه
Impact of quality control on radiation doses received by patients undergoing abdomen X-ray examination in ten hospitals
ABSTRACT Background: The X-ray machines used for radiodiagnosis should meet certain quality assurance (QA) programmes . These are necessary to have good quality radiographs at reasonably low exposure to patients. Materials and Methods: Dose reduction methods in abdomen X-ray examination were carried out in 10 hospitals in Tehran. This paper presents the work, which was implemented on 200 ...
متن کاملHVL evaluation of orthovoltage X-ray machine using EGSnrc code of simulation
Background: Making use of the orthovoltage machines in Radiotherapy, is one of the routine methods for the treatment of the superficial lesions. In this study, an important determinant of X-ray quality, the HVL (Half Value Layer), has been evaluated. Materials and Methods: The HVLs of a orthovoltage X-ray machine in 120 and 180 kVp are measured, using an empirical method, in which the HVLs are ...
متن کاملEvaluation of a systemic change of Superficial X-ray tube characteristics
Introduction: Very low, Low and Medium X-ray machines are used extensively for Superficial Radiation Therapy mostly used for Basal Cell, Squamous Cell Carcinoma, and Melanoma skin cancers. In most of cases, Superficial X-ray Therapy (SXRT) is preferred to Electron beams generated using a linear accelerator. SXRT tube characteristics may vary with the use of the machine for a lo...
متن کاملPerformance Evaluation of Diagnostic X-Ray Equipment Regarding the Hospital Size in the Republic of Korea
Introduction: The Republic of Korea has developed a national standard based on which diagnostic X-ray equipment must be tested every 3 years. Accordingly, the performance of X-ray equipment used in all hospitals is evaluated by national certification bodies in compliance with the safety management regulations for X-ray equipment. However, if the equipment i...
متن کاملPatient dose in routine X-ray examinations in Yazd state
Background: Medical x-rays are the largest man-made source of public exposure to ionizing radiation. It is important to avoid conditions where the amount of radiation used is more than that needed for the procedure. Materials and Methods: The Entrance Skin Exposure (ESE) measurement was conducted for quality control of x-ray machines and survey of operator’s experimental techniques. The ESEs we...