Simultaneous Determination of Valsartan and Hydrochlorothiazide in Tablets by RP-HPLC
نویسندگان
چکیده
A simple, reproducible and efficient reverse phase high performance liquid chromatographic method was developed for simultaneous determination of valsartan and hydrochlorothiazide in tablets. A column having 200 x 4.6 mm i.d. in isocratic mode with mobile phase containing methanol:acetonitrile:water:isopropylalcohol (22:18:68:2; adjusted to pH 8.0 using triethylamine; v/v) was used. The flow rate was 1.0 ml/min and effluent was monitored at 270 nm. The retention time (min) and linearity range (mug/ml) for valsartan and hydrochlorothiazide were (3.42, 8.43) and (5-150, 78-234), respectively. The developed method was found to be accurate, precise and selective for simultaneous determination of valsartan and hydrochlorothiazide in tablets.
منابع مشابه
Quantitative determination of three angiotensin-II-receptor antagonists in presence of Hydrochlorothiazide by RP-HPLC in their tablets preparations
Losartan potassium, Valsartan , Telmisartan and Irbesartan are angiotensin-II-receptor antagonists (ARA II) group which used in treatment of hypertension alone or in combination with other drugs mainly Hydrochlorothiazide. RP- HPLC method was developed for the assay of three angiotensin-II-receptor antagonists (ARA-IIs) in presence of Hydrochlorothiazide. The method was performed by reversed ph...
متن کاملQuantitative determination of three angiotensin-II-receptor antagonists in presence of Hydrochlorothiazide by RP-HPLC in their tablets preparations
Losartan potassium, Valsartan , Telmisartan and Irbesartan are angiotensin-II-receptor antagonists (ARA II) group which used in treatment of hypertension alone or in combination with other drugs mainly Hydrochlorothiazide. RP- HPLC method was developed for the assay of three angiotensin-II-receptor antagonists (ARA-IIs) in presence of Hydrochlorothiazide. The method was performed by reversed ph...
متن کاملRapid and Sensitive Tlc and Hplc with On-line Wavelength Switching Methods for Simultaneous Quantitation of Amlodipine, Valsartan and Hydrochlorothiazide in Pharmaceutical Dosage Forms
Two RP-HPLC and TLC methods were developed and validated according to the ICH guidelines for the simultaneous determination of Amlodipine, Valsartan and Hydrochlorothiazide in tablet dosage form. The two methods are simple, rapid and selective. Complete HPLC separation was achieved using Nucleosil C18 column and acetonitrile/methanol/isopropyl alcohol (55:41:4 by volume) mixture as the mobile p...
متن کاملSimultaneous Determination of Losartan and Hydrochlorothiazide in Pharmaceutical Preparations by Derivative and Ratio Derivative Spectrophotometry
Background & Aims: Losartan is a non-peptide potent antihypertensive agent that acts through blocking angiotensin II receptors. Hyzaar® is a combination product that contains two drugs, losartan and hydrochlorothiazide, used to lower high blood pressure. There are some reports regarding simultaneous measurement of the drugs in pharmaceutical and biological samples which includes HPLC, CE, CEC, ...
متن کاملSimple RP-HPLC method for determination of triple drug combination of valsartan, amlodipine and hydrochlorothiazide in human plasma.
A simple RP-HPLC method for the quantification of valsartan (VAL), amlodipine (AML) and hydrochlorothiazide (HCT) in human plasma was developed and validated. VAL, AML and HCT were resolved using a Gemini C18 column and mobile phase gradient starting from 20 % acetonitrile and 80 % 10 mmol L(-1) ammonium formate (V/V, pH 3.5 ± 0.2, by formic acid) to 70 % acetonitrile and 30 % 10 mmol L(-1) amm...
متن کامل