Differential electrolytic potentiometric determination of some amino acids in dosage forms.
نویسندگان
چکیده
The application of direct-current differential electrolytic potentiometry to the nonaqueous titration of amino acids was investigated. The basic character of amino acids in acetic acid was enhanced to permit their direct titration with perchloric acid. A pair of antimony electrodes was used as an indicating system. The shapes of the titration curves obtained were almost symmetrical with sharp peaks. The optimum current density for those titrations was found to be 1-2 microA/cm2. The procedure was applied successfully to the determination of certain amino acids in drug formulations, and the results were favorably compared statistically with those obtained by official methods.
منابع مشابه
Flow Injection Potentiometric Assay of Hexoprenaline in Its Pure State, Pharmaceutical Preparations, and Biological Samples
Different hexoprenaline (Hx(2)SO(4)) conventional and coated wire electrodes were constructed and evaluated. Membranes were based on hexoprenalinium phosphotungstate (Hx-PTA) and hexporenalinium phosphomolybdate (Hx-PMA). The electrodes were fully characterized in terms of their composition, response time, life span, pH, and temperature and then were applied to the potentiometric determination ...
متن کاملMetal-Ion-Coordinating Properties of Various Amino Acids, Investigation of the Essential Function in Biological Systems regarding to their Nano-Structure
The acidity constants of some amino acids (Am) were determined by potentiometric pH titration. The stability constants of the 1:1 complexes formed between M2+: Ca2+, Mg2+, Mn2+, Co2+, Ni2+, Cu2+ or Zn2+ and Am2-, were determined by potentiometric pH titration in aqueous solution (I = 0.1 M, NaNO3, 25°C). The order of the stability constants was reported. It is shown that the stability of the bi...
متن کاملMetal-Ion-Coordinating Properties of Various Amino Acids, Investigation of the Essential Function in Biological Systems regarding to their Nano-Structure
The acidity constants of some amino acids (Am) were determined by potentiometric pH titration. The stability constants of the 1:1 complexes formed between M2+: Ca2+, Mg2+, Mn2+, Co2+, Ni2+, Cu2+ or Zn2+ and Am2-, were determined by potentiometric pH titration in aqueous solution (I = 0.1 M, NaNO3, 25°C). The order of the stability constants was reported. It is shown that the stability of the bi...
متن کاملIon-Selective Carbon Paste Electrode Based on 2-Amino-N-benzthioazolyl Benzamide (ABTB) for Determination of Copper (II) by Potentiometric Method
2-Amino-N-benzthioazolyl benzamide (ABTB) was synthesized, characterized and used for thefabrication of a potentiometric sensor for Cu2+ metal ions. The electrode exhibits linear response to Cu(II) over a wide concentration range (4.79×10 -8 – 1.85×10 -1 M) with Nernstian slope of 30 ± 1.5 mVper decade. The electrode can be used in the pH range from 2 to 9. It has a fast response time of about1...
متن کاملA New Potentiometric Sensor for Determination and Screening Phenylalanine in Blood Serum Based on Molecularly Imprinted Polymer
Methods routinely utilized for detection of phenylalanine in new-born blood consist of enzymatic assays, lacking sensitivity and HPLC assays which are expensive and time-consuming to conduct. We, here, report for the first time, the construction of a phenylalanine sensitive electrode, on the basis of a selective molecularly imprinted polymer, offering sensitivity, economy and ease of use for th...
متن کاملذخیره در منابع من