Impact of Series FACTS Devices (GCSC, TCSC and TCSR) on Distance Protection Setting Zones in 400 kV Transmission Line
نویسندگان
چکیده
منابع مشابه
A Comparative Study of GCSC and TCSC Effects on MHO Distance Relay Setting in Algerian Transmission Line
This paper presents a comparative study of the performance of distance relays for transmission line high voltage (HV) 400 kV in Eastern Algerian transmission networks at Group Sonelgaz compensated by two different series Flexible AC Transmission System (FACTS) i.e. GTO Controlled Series Capacitor (GCSC) and Thyristor Controlled Series Capacitor (TCSC) connected at midpoint of an electrical tran...
متن کاملA Comparative Study of Ground Fault Analysis for a Practical Case of a Transmission Line Equipped with Different Series FACTS Devices
Due to the rising power demand and increasing population worldwide, electrical power networks have been extensively growing and striving to satisfy the escalating loads. This necessitates the need for using Flexible AC Transmission System (FACTS) devices which have become indispensable during normal and abnormal operating conditions. This paper investigates the impact of using series FACTS devi...
متن کاملModified Setting Numerical Distance Protection of Power Transmission Line in Presence Tcsc Using Iec 62850 Communication Protocol
This paper presents a study of the performance of numerical distance relay for a 400 kV electrical transmission line compensated by series Flexible AC Transmission System (FACTS) i.e. Thyristor Controlled Series Capacitor (TCSC) is connected in the middle of the transmission line and can be used in voltage mode control or reactive power injection mode, and damping of power system oscillations i...
متن کاملEffect of TCSR on Measured Impedance by Distance Protection in Presence Single Phase to Earth Fault
This paper presents the impact study of apparent reactance injected by series Flexible AC Transmission System (FACTS) i.e. Thyristor Controlled Series Reactor (TCSR) on the measured impedance of a 400 kV single electrical transmission line in the presence of phase to earth fault with fault resistance. The study deals with an electrical transmission line of Eastern Algerian transmission networks...
متن کاملImpact of GCSC on Measured Impedance by Distance Relay in the Presence of Single Phase to Earth Fault
This paper presents the impact study of GTO Controlled Series Capacitor (GCSC) parameters on measured impedance (Zseen) by MHO distance relays for single transmission line high voltage 220 kV in the presence of single phase to earth fault with fault resistance (RF). The study deals with a 220 kV single electrical transmission line of Eastern Algerian transmission networks at Group Sonelgaz (Alg...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2017