Left ventricle remodeling predicts the recurrence of ventricular tachyarrhythmias in implantable cardioverter defibrillator recipients for secondary prevention

نویسندگان

  • Wei-Chieh Lee
  • Huang-Chung Chen
  • Yung-Lung Chen
  • Tzu-Hsien Tsai
  • Kuo-Li Pan
  • Yu-Sheng Lin
  • Mien-Cheng Chen
چکیده

BACKGROUND Implantable cardioverter defibrillator (ICD) is an effective treatment for secondary prevention of ventricular tachycardia/ventricular fibrillation (VT/VF). Left ventricular (LV) remodeling may develop before ICD implant and over time. However, it remains unclear how LV remodeling affects subsequent risk for recurrence VT/VF in ICD recipients under optimal medical therapy. METHODS From May of 2004 to June of 2015, 144 patients received ICD implantation for secondary prevention were enrolled in this study. All information interrogated from ICD devices during follow-up or ICD therapy history (anti-tachycardia pacing and shock therapy) were reviewed and validated the occurrences of VT/VF. RESULTS At a mean follow-up of 1110.5 ± 860.6 days, 53 patients (36.8%) had recurrence of VT/VF episodes and 91 patients had no recurrence of VT/VF episode after ICD implant. Left ventricular end-diastolic volume (LVEDV) > 163.5 mL had significant predictive value for VT/VF recurrence (area under the curve: 0.602, p = 0.041). Moreover, the percentage of patients with LVEDV >163.5 mL was significantly higher in patients with recurrent VT/VF than patients without recurrent VT/VF (62.3 vs 40.0%, p = 0.010). Left ventricular ejection fraction ≤ 30% (p = 0.031), LVEDV > 163.5 mL (p = 0.012) and QRS width > 125 msec (p = 0.049) were significant predictors for VT/VF recurrence by univariate Cox regression analysis. However, only LVEDV > 163.5 mL (hazard ratio: 2.549, 95% confidence interval: 1.249 ~ 5.201, p = 0.010) and QRS width > 125 msec (hazard ratio: 2.173, 95% confidence interval: 1.030 ~ 4.586, p = 0.042) were independent predictors for recurrence of VT/VF after multivariable adjustment. CONCLUSION LV remodeling and QRS width > 125 msec were independent predictors for VT/VF recurrence in secondary prevention ICD recipients under optimal medical therapy, independent of LV ejection fraction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

Implantable cardioverter defibrillator therapy: ten years experience in a medical center.

BACKGROUND An implantable cardioverter defibrillator (ICD) is the therapy of choice for survivors of life-threatening ventricular tachyarrhythmias or sudden cardiac death. To date there is little data concerning the clinical features and outcome of ICD therapy among Taiwanese. This study identifies factors related to the outcome of ICD therapy over a ten-year period at this institution. METHO...

متن کامل

Progressive electrical remodeling in apical hypertrophic cardiomyopathy leading to implantable cardioverter-defibrillator sensing failure during ventricular fibrillation

Introduction Although there is a paucity of randomized trials evaluating outcomes after primary-prevention implantable cardioverter-defibrillator (ICD) placement for patients with hypertrophic cardiomyopathy, guidelines recommend ICD placement for certain patients with the disease. Apical hypertrophic cardiomyopathy (AHCM) is one pattern of disease manifestation with unique characteristics. Hyp...

متن کامل

Trouble Shooting of ICD Therapy: Inappropriate Shock

Patients with an implantable cardioverter defibrillator (ICD) can undergo inappropriate therapies (shock or antitachycardia pacing) if electrical activity not originating in the ventricle is wrongly recognized as ventricular by the device. Inappropriate therapy leading to shocks is not innocuous; consequences include pain and its psychological sequelae, particularly anxiety, as well as inductio...

متن کامل

Implantable cardioverter defibrillator therapy in patients with cardiac sarcoidosis.

UNLABELLED ICD Shocks in Cardiac Sarcoidosis. BACKGROUND An implantable cardioverter defibrillator (ICD) is indicated for some patients with cardiac sarcoidosis (CS) for prevention of sudden death. However, there are little data regarding the event rates of ICD therapies in these patients. We sought to identify the incidence and characteristics of ICD therapies in this patient population. M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2016