An open-source automated platform for three-dimensional visualization of subdural electrodes using CT-MRI coregistration.

نویسندگان

  • Allan A Azarion
  • Jue Wu
  • Allison Pearce
  • Veena T Krish
  • Joost Wagenaar
  • Weixuan Chen
  • Yuanjie Zheng
  • Hongzhi Wang
  • Timothy H Lucas
  • Brian Litt
  • James C Gee
  • Kathryn A Davis
چکیده

OBJECTIVE Visualizing implanted subdural electrodes in three-dimensional (3D) space can greatly aid in planning, executing, and validating resection in epilepsy surgery. Coregistration software is available, but cost, complexity, insufficient accuracy, or validation limit adoption. We present a fully automated open-source application, based on a novel method using postimplant computerized tomography (CT) and postimplant magnetic resonance (MR) images, for accurately visualizing intracranial electrodes in 3D space. METHODS CT-MR rigid brain coregistration, MR nonrigid registration, and prior-based segmentation were carried out on seven patients. Postimplant CT, postimplant MR, and an external labeled atlas were then aligned in the same space. The coregistration algorithm was validated by manually marking identical anatomic landmarks on the postimplant CT and postimplant MR images. Following coregistration, distances between the center of the landmark masks on the postimplant MR and the coregistered CT images were calculated for all subjects. Algorithms were implemented in open-source software and translated into a "drag and drop" desktop application for Apple Mac OS X. RESULTS Despite postoperative brain deformation, the method was able to automatically align intrasubject multimodal images and segment cortical subregions, so that all electrodes could be visualized on the parcellated brain. Manual marking of anatomic landmarks validated the coregistration algorithm with a mean misalignment distance of 2.87 mm (standard deviation 0.58 mm)between the landmarks. Software was easily used by operators without prior image processing experience. SIGNIFICANCE We demonstrate an easy to use, novel platform for accurately visualizing subdural electrodes in 3D space on a parcellated brain. We rigorously validated this method using quantitative measures. The method is unique because it involves no preprocessing, is fully automated, and freely available worldwide. A desktop application, as well as the source code, are both available for download on the International Epilepsy Electrophysiology Portal (https://www.ieeg.org) for use and interactive refinement.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional visualization of subdural electrodes for presurgical planning.

BACKGROUND Accurate localization and visualization of subdural electrodes implanted for intracranial electroencephalography in cases of medically refractory epilepsy remains a challenging clinical problem. OBJECTIVE We introduce a technique for creating accurate 3-dimensional (3D) brain models with electrode overlays, ideal for resective surgical planning. METHODS Our procedure uses postimp...

متن کامل

Rapid and fully automated visualization of subdural electrodes in the presurgical evaluation of epilepsy patients.

For rapid visualization of subdural electrodes with respect to cortical and subcortical structures, we describe a novel and fully automated method based on coregistration, normalization, optional cerebellum masking, and volume rendering of 3D MR imaging data taken before and after implantation. The key step employs the skull-stripped preimplantation image as a mask to also remove the skull in t...

متن کامل

Triple-technique (MR imaging, single-photon emission CT, and CT) coregistration for image-guided surgical evaluation of patients with intractable epilepsy.

Ictal and interictal single-photon emission CT (SPECT) play an increasingly important role in the surgical evaluation of patients with epilepsy. We present a method of coregistration of MR, SPECT, and CT images to correlate structural data (MR imaging), blood flow changes (SPECT), and location of subdural electrodes (CT) for patients undergoing image-guided surgical treatment of epilepsy. MR-SP...

متن کامل

Three-dimensional localization of cortical electrodes in deep brain stimulation surgery from intraoperative fluoroscopy

Electrophysiological recordings from subdural electrocorticography (ECoG) electrodes implanted temporarily during deep brain stimulation (DBS) surgeries offer a unique opportunity to record cortical activity for research purposes. The optimal utilization of this important research method relies on accurate and robust localization of ECoG electrodes, and intraoperative fluoroscopy is often the o...

متن کامل

An interactive technique for three-dimensional image registration: validation for PET, SPECT, MRI and CT brain studies.

UNLABELLED A multipurpose three-dimensional registration technique was validated with PET, SPECT, CT and MRI scans, which had been obtained under normal clinical conditions. In contrast to fully automated procedures, this coregistration method is highly interactive, which has the advantage that it does not impose rigid restrictions by data type and by alterations in normal anatomy or brain func...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Epilepsia

دوره 55 12  شماره 

صفحات  -

تاریخ انتشار 2014