چکیده

OBJECTIVES Validation studies of European system for cardiac operative risk evaluation II (EuroSCORE II) have been limited to European datasets. Therefore, the aims of this study were to assess the performance of EuroSCORE II in a large multicentre US database, and compare it with the Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM). In addition, implications for patient selection for transcatheter aortic valve implantation (TAVI) were explored. METHODS EuroSCORE II and the STS-PROM were calculated for 50 588 patients from a multi-institutional statewide database of all cardiac surgeries performed since 2003. Model performance was assessed using the area under the receiver operator curve (AUC), observed vs expected (O:E) ratios and calibration plots. Analyses were performed for isolated coronary artery bypass grafting (CABG) (n = 40 871), aortic valve replacement (AVR) (n = 4107), AVR + CABG (n = 3480), mitral valve (MV) replacement (n = 1071) and MV repair (n = 1059). RESULTS The overall in-hospital mortality rate was 2.1%. EuroSCORE II was outperformed by the STS-PROM in the overall cohort with regard to discrimination (AUC = 0.77 vs 0.81, respectively; P < 0.001) and calibration (O:E = 0.68 vs 0.80, respectively). Discrimination for CABG was worse with EuroSCORE II (AUC = 0.77 vs STS-PROM: 0.81, P < 0.001). For other procedures discrimination was similar: AVR (AUC = 0.71 vs STS-PROM: 0.74, P = 0.40), AVR + CABG (AUC = 0.72 vs STS-PROM: 0.74, P = 0.47), MV repair (AUC = 0.82 vs STS-PROM: 0.86, P = 0.55) and MV replacement (AUC = 0.78 vs STS-PROM: 0.79, P = 0.69). Calibration of EuroSCORE II was worse for CABG (O:E = 0.68 vs STS-PROM: 0.80), similar in AVR + CABG (O:E = 0.76 vs STS-PROM: 0.70) and MV repair (O:E = 0.64 vs STS-PROM: 0.67), while EuroSCORE II may be more accurate in AVR (O:E = 0.96 vs STS-PROM: 0.76). Performance of both models improved when only recent cases (after 1 January 2008) were used. Ongoing TAVI trials aimed at patients with an estimated 4-10% risk of mortality are enrolling patients with mean estimated risks of 6.2% (EuroSCORE II) or 6.0% (STS-PROM), and an actual mortality rate of 4.6% (EuroSCORE II) or 4.8% (STS-PROM). CONCLUSIONS In a large US multicentre database, the STS-PROM performs better than EuroSCORE II for CABG. However, EuroSCORE II is a reasonable alternative in low-risk CABG patients and in those undergoing other cardiac surgical procedures. Clinical trials and physicians that use these scores recruit and treat patients who are at a lower risk than anticipated. This potentially leads to overtreatment with an investigational device. Decision-making should not solely be based on risk scores, but should comprise multidisciplinary heart team discussions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Early and Late Mortality in Patients Undergoing Transcatheter Aortic Valve Implantation: Comparison of the Novel EuroScore II with Established Risk Scores

Objectives: In the evaluation of patients considered for transcatheter aortic valve implantation (TAVI), the Euro­ Score II might be superior to established risk scores. Methods: We assessed the performance of the EuroScore II in pre­ dicting mortality in a cohort of 350 TAVI patients. Results: The EuroScore II and the logistic EuroScore were higher in nonsurvivors compared to survivors at 30 d...

متن کامل

Early and Late Mortality in Patients Undergoing Transcatheter Aortic Valve Implantation: Comparison of the Novel EuroScore II with Established Risk Scores

Objectives: In the evaluation of patients considered for transcatheter aortic valve implantation (TAVI), the Euro­ Score II might be superior to established risk scores. Methods: We assessed the performance of the EuroScore II in pre­ dicting mortality in a cohort of 350 TAVI patients. Results: The EuroScore II and the logistic EuroScore were higher in nonsurvivors compared to survivors at 30 d...

متن کامل

Early and late mortality in patients undergoing transcatheter aortic valve implantation: comparison of the novel EuroScore II with established risk scores.

OBJECTIVES In the evaluation of patients considered for transcatheter aortic valve implantation (TAVI), the EuroScore II might be superior to established risk scores. METHODS We assessed the performance of the EuroScore II in predicting mortality in a cohort of 350 TAVI patients. RESULTS The EuroScore II and the logistic EuroScore were higher in nonsurvivors compared to survivors at 30 days...

متن کامل

Is the EuroSCORE II best suited for reoperative risk estimation in patients with structural deterioration of aortic bioprostheses?

BACKGROUND Operative risk prediction systems (logistic EuroSCORE I, EuroSCORE II and STS Score) are employed together with multidisciplinary discussion to contraindicate conventional surgery in patients with valvular heart disease and propose the employment of alternative transcatheter procedures. The EuroSCORE I has been reported to underperform in these circumstances; we hypothesize that the ...

متن کامل

Valvular Heart Disease One-Year Outcomes of Cohort 1 in the Edwards SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry The European Registry of Transcatheter Aortic Valve Implantation Using the Edwards SAPIEN Valve

Background—Transcatheter aortic valve implantation was developed to provide a therapeutic option for patients considered to be ineligible for, and to mitigate mortality and morbidity associated with, high-risk surgical aortic valve replacement. Methods and Results—The Edwards SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry was designed to assess initial post commercial clinical t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 46 3  شماره 

صفحات  -

تاریخ انتشار 2014