Correlation of pattern electroretinogram with optic disc cup shape in ocular hypertension.

نویسندگان

  • T Salgarello
  • A Colotto
  • B Falsini
  • L Buzzonetti
  • L Cesari
  • G Iarossi
  • L Scullica
چکیده

PURPOSE To evaluate the correlation of pattern electroretinogram (PERG), an index of inner retinal function, with confocal scanning laser (CSLO) optic disc structural parameters in ocular hypertension (OHT). METHODS Thirty-four patients with OHT, normal white-on-white (Humphrey 30-2) perimetry, and normal clinical optic discs were examined with PERG and CSLO disc analysis. Two groups of normal subjects (n = 38 and 18, for PERG and CSLO, respectively) and a group of 12 patients with early open-angle glaucoma (EOAG) were also tested. Pattern electroretinogram amplitudes were measured in response to sinusoidal gratings of variable spatial frequency (0.58-5.8 cycles/degree), modulated in counter-phase at 7.5 Hz. Morphometric optic disc parameters were obtained by the Heidelberg Retina Tomograph (HRT), either globally or from predefined disc sectors. In addition to standard parameters, the cup shape measure, an index of depth variation and steepness of the cup walls, was determined. RESULTS In individual OHT patients, PERG amplitudes at 2.6 cycles/degree were negatively correlated with cup shape measures (r = -0.43, P < 0.01) obtained from analysis of the inferotemporal (IT) sector. No significant correlations were found for the other parameters. On average, the cup shape measures derived from IT sector or global analysis were significantly (P < 0.01) worse, and closer to the measures of EOAG patients, in OHT patients with abnormal PERG compared with those with normal PERGs. The cup shape measure displayed a low sensitivity (20%) and a high specificity (100%) in predicting PERG abnormalities in individual OHT patients. CONCLUSIONS The results indicate that in OHT there is a significant although weak correlation between PERG amplitude and the shape of the optic disc cup, suggesting a parallel involvement of both function and morphology. Combined PERG and optic disc cup structural analysis is of potential diagnostic value to detect early damage to optic nerve head in individual OHT patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flicker-evoked response measured at the optic disc rim is reduced in ocular hypertension and early glaucoma.

PURPOSE To determine in patients with ocular hypertension (OHT) or early glaucoma (EOAG) the change in blood flow measured at the neuroretinal rim of the optic disc in response to a 15-Hz diffuse green luminance flicker, a stimulus that activates predominantly the ganglion cell magnocellular pathway. METHODS Thirteen patients with EOAG, 29 with OHT, and 16 age-matched control subjects, all wi...

متن کامل

Correlation of peripheral displacement thresholds and optic disc parameters in ocular hypertension.

Both peripheral displacement thresholds and measurement of optic disc parameters have been advocated in the early diagnosis of glaucoma at the stage before scotomata are detected on conventional visual field assessment. The peripheral movement displacement thresholds were measured in 50 eyes of 50 patients with ocular hypertension and a significant correlation was found with neuroretinal rim ar...

متن کامل

Scanning laser ophthalmoscopy of the optic nerve head in exfoliation glaucoma and ocular hypertension with exfoliation syndrome.

AIMS To study the relation between optic nerve head topography (Heidelberg retina tomograph, HRT) and disc area, visual field index mean defect (MD), and intraocular pressure (IOP), and to see whether change in HRT parameters is associated with change in MD in a prospective follow up. METHODS 80 consecutive patients (69 patients with exfoliation glaucoma and 11 with ocular hypertension combin...

متن کامل

Assessment of cup-to-disc ratio with slit-lamp funduscopy, Heidelberg Retina Tomography II, and stereoscopic photos.

PURPOSE To compare optic disc measurements achieved by slit-lamp funduscopy, Heidelberg Retina Tomography II (HRT II), and stereoscopic optic nerve photos (SONP) in glaucomatous, ocular hypertensive, and normal eyes. METHODS A total of 176 eyes (glaucomatous [n=87], ocular hypertensive [n=40], and normal eyes [n=49]) of 90 participants were studied. Each participant underwent a full ophthalmi...

متن کامل

Photogrammetry of the optic disc in glaucoma and ocular hypertension with simultaneous stereo photography.

Stereophotogrammetric evaluations of the optic cup were performed for normal, ocular hypertensive, and glaucomatous eyes. Average volume, area, and depth measurements were progressively larger from normal to ocular hypertensive to glaucomatous eyes, although the distributions of individual values exhibited considerable overlap among the three groups. Similar results were obtained for volume, ar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 40 9  شماره 

صفحات  -

تاریخ انتشار 1999