Incidence of propofol infusion syndrome during noninvasive radiofrequency ablation for atrial flutter or fibrillation.
نویسندگان
چکیده
BACKGROUND Propofol infusion syndrome is first manifest by unexplained metabolic acidosis. Its incidence is unknown. METHODS Charts of all patients undergoing nonsurgical, catheter radiofrequency ablation for atrial flutter or fibrillation from 1999 through 2001 at Mayo Clinic Rochester, who received propofol and had an arterial blood gas drawn during the procedure, were reviewed retrospectively for metabolic acidosis, prospectively defined as base excess -2 or less. Of 301 radiofrequency ablation cases, 55 had an arterial blood gas. Virtually all radiofrequency ablation patients received propofol, so they could not be used as nonpropofol controls. Instead, all carotid endarterectomy patients in 2000 who did not receive propofol and had an arterial blood gas drawn after anesthetic induction and before surgical incision were used as a comparator group. RESULTS In propofol radiofrequency ablation patients with no apparent cause of metabolic acidosis besides propofol, 13 of 55 (24%) had base excess of -2 or less, versus 22 of 267 carotid patients (8.2%) (P<0.01). Maximal negative base excess was -4.2+/-1.7 in these propofol patients and was not correlated with propofol dose, age, or fluid dose, versus base excess of -3.2+/-1.5 in carotid patients (P>0.05). Propofol patients received prolonged anesthetics (7 h) and high-dose propofol (20 mg/kg). CONCLUSIONS This is the first incidence estimate of metabolic acidosis during prolonged propofol infusion and suggests that it is not rare. The study is limited by its retrospective nature and by the lack of baseline arterial blood gas data and will require confirmation by prospective study.
منابع مشابه
Acute effects of left atrial radiofrequency ablation on atrial fibrillation.
INTRODUCTION Acutely, when left atrial ablation is performed during atrial fibrillation (AF), the AF may persist and require cardioversion, or it may convert to sinus rhythm or to atrial tachycardia/flutter. The prevalence of these acute outcomes has not been described. METHODS AND RESULTS Left atrial ablation, usually including encirclement of the pulmonary veins, was performed during AF in ...
متن کاملCatheter ablation of atrial flutter using radiofrequency energy.
Sixteen patients with type I atrial flutter underwent an attempt at radiofrequency catheter ablation (8 women, 8 men, mean age 53 +/- 11 years). The primary criterion used to identify sites for radiofrequency energy delivery was the identification of a fractionated electrogram. Radiofrequency energy was delivered for 20 to 30 seconds. Radiofrequency catheter ablation was acutely successful in 1...
متن کاملAtrial fibrillation and its determinants after radiofrequency ablation of chronic common atrial flutter
AIM Atrial fibrillation (AFib) is a major clinical issue and its occurrence is the main problem after catheter ablation of atrial flutter. The long-term occurrence of AFib after common atrial flutter ablation is still matter of debate as it may influence the therapeutic approach. So, the aim of our study was to analyze the determinants and the time course of AFib after radiofrequency catheter a...
متن کاملAtrial Tachycardias Following Atrial Fibrillation Ablation
One of the most important proarrhythmic complications after left atrial (LA) ablation is regular atrial tachycardia (AT) or flutter. Those tachycardias that occur after atrial fibrillation (AF) ablation can cause even more severe symptoms than those from the original arrhythmia prior to the index ablation procedure since they are often incessant and associated with rapid ventricular response. D...
متن کاملSurgical ablation of atrial fibrillation with a novel bipolar radiofrequency device.
OBJECTIVE When used for epicardial ablation, unipolar devices do not predictably yield transmural scars. Bipolar radiofrequency proved highly effective on the animal model, but clinical experience is still initial. We describe acute electrophysiologic findings and follow-up results of epicardial ablation with a novel bipolar radiofrequency device. METHODS A bipolar ablator was used to perform...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesiology
دوره 106 6 شماره
صفحات -
تاریخ انتشار 2007