UNLABELLED Compared with conventional, whole-organ, S-factor-based dosimetry, 3-dimensional (3D), patient-specific dosimetry better accounts for radionuclide distribution and anatomic patient variability. Its accuracy, however, is limited by the quality of the cumulated activity information that is provided as input. This input has typically been obtained from SPECT and planar imaging studies. The objective was to implement and evaluate PET-based, patient-specific, 3D dosimetry for thyroid cancer patients. METHODS Three to 4 PET imaging studies were obtained over a 7-d period in 15 patients with metastatic thyroid carcinoma after administration of (124)I-NaI. Subsequently, patients were treated with (131)I on the basis of established clinical parameters. Retrospective dosimetry was performed using registered (124)I PET images that were corrected for the half-life difference between (124)I and (131)I. A voxel-by-voxel integration, over time, of the resulting (131)I-equivalent PET-derived images was performed to provide a single 3D dataset representing the spatial distribution of cumulated activity values for each patient. Image manipulation and registration were performed using Multiple Image Analysis Utility (MIAU), a software package developed previously. The software package, 3D-Internal Dosimetry (3D-ID), was used to obtain absorbed dose maps from the cumulated activity image sets. RESULTS Spatial distributions of absorbed dose, isodose contours, dose-volume histograms (DVHs), and mean absorbed dose estimates were obtained for a total of 56 tumors. Mean absorbed dose values for individual tumors ranged from 1.2 to 540 Gy. The absorbed dose distribution within individual tumors was widely distributed ranging from a minimum of 0.3 to a maximum of 4,000 Gy. CONCLUSION (124)I PET-based, patient-specific 3D dosimetry is feasible, and sequential PET can be used to obtain cumulated activity images for 3D dosimetry.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recombinant Human Thyroid-Stimulating Hormone Versus Thyroid Hormone Withdrawal in 124I PET/CT-Based Dosimetry for 131I Therapy of Metastatic Differentiated Thyroid Cancer.

Patients with metastatic differentiated thyroid cancer (DTC) may be prepared using either thyroid-stimulating hormone withdrawal (THW) or recombinant human thyroid-stimulating hormone (rhTSH) injections before 131I administration for treatment. The objective of this study was to compare the absorbed dose to the critical organs and tumors determined by 124I PET/CT-based dosimetry for 131I therap...

متن کامل

124I PET and 3-Dimensional–Internal Dosimetry (3D–ID) Software

1Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York; 2Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, New York; 3Department of Nuclear Medicine, Philips-University of Marburg, Marburg, Germany; 4Department of Medicine, Memorial Sloan-Kettering Cancer Center, New York, New York; and 5Department of Radiology, School of Medicine, Jo...

متن کامل

Optimized 124I PET dosimetry protocol for radioiodine therapy of differentiated thyroid cancer.

UNLABELLED Iodine kinetics and lesion dose per administered 131I activity (LDpA) of differentiated thyroid cancer metastases were determined using 124I PET. These data were analyzed to derive an optimized dosimetry protocol. METHODS We evaluated the time-activity-concentration curves of 37 lesions in 17 patients who had undergone thyroidectomies. LDpA determination involved 124I PET images ac...

متن کامل

Determination of organ doses in radioiodine therapy using medical internal radiation dosimetry (MIRD) method

Background: Radioiodine therapy has proven to be an effective method in the treatment of patients with differentiated thyroid carcinoma after thyroidectomy. The scope of this study is to describe a method to obtain the dose of organs using medical internal radiation dosimetry (MIRD) method. At the end, the results of MIRD calculations were compared with thermoluminescent dosimeter (TLD...

متن کامل

Options for radionuclide therapy: from fixed activity to patient-specific treatment planning.

The therapeutic use of radioisotopes in medicine as unsealed sources has a long history dating back to the 1930s. The established and continuing objectives are to provide radiation dose to the target tissue at the desired cytotoxic level while avoiding or minimizing toxic effects. Selected radionuclide therapy protocols including 32P for polycythemia vera, 131I for Graves' disease, and 131I for...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 45 8  شماره 

صفحات  -

تاریخ انتشار 2004