Measurement of iodide in urine using the iodide-selective ion electrode.

نویسندگان

  • Y Yabu
  • K Miyai
  • S Hayashizaki
  • Y Endo
  • N Hata
  • Y Iijima
  • R Fushimi
چکیده

A simple and rapid way to measure the concentration of iodide in urine with an iodide-selective ion electrode was described. Potentiometric equilibrium was attained in less than 5 min, and a linear calibration curve was obtained over the potassium iodide (KI) concentration range of 10(-2) to 10(-6) M. The coefficients of variation ranged from 6.2 to 10.0% within assay, and 5.4 to 14.4% between assays. The serial dilution of 3 urine samples with different concentration of iodide showed good linear correlations passing through zero. In practice, the chloride ions in urine did not cause serious errors in the measurement of iodide at molar ratios of chloride ion to iodide up to 2 X 10(4). A good linear correlation was obtained between iodide concentrations in urine determined by the electrode method and by the conventional chemical method (r = 0.92). A linear correlation was also observed between the iodide concentrations of 24 h collected urine and those of single morning urine (r = 0.91). The normal iodide content in single morning urine specimens from 127 Japanese people was 5.3 to 62.0 X 10(-6) moles/g creatinine.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Iodide selective membrane electrode based on copper (Π)-bis-Nphenilsalicyldenaminato complex

An iodide ion-selective PVC membrane sensor based on copper (Π)-bis-Nphenilsalicyldenaminatocomplex as a novel sensing material is successfully developed. Theelectrode showed a good selectivity for iodide ion with respect to common inorganic anions. Thesensor exhibited a good linear response with slope of _58.6 ± 0.4 mV per decade over theconcentration range of 5.0 × 10-6 to 1.0 × 10-1 mol L-1,...

متن کامل

Urinary iodide excretion measured with an iodide-selective ion electrode: studies on normal subjects of varying ages and patients with thyroid diseases.

As a part of studies concerning clinical application of the measurement of urinary iodide with an iodide-selective ion electrode, we report here the reference values for the iodide content or concentration in morning spot urine specimens from normal subjects of varying ages and studies with patients with thyroid diseases in Japan. The number distribution of the iodide content or concentration i...

متن کامل

A Selective Iodide Ion Sensor Electrode Based on Functionalized ZnO Nanotubes

In this research work, ZnO nanotubes were fabricated on a gold coated glass substrate through chemical etching by the aqueous chemical growth method. For the first time a nanostructure-based iodide ion selective electrode was developed. The ZnO nanotubes were functionalized with miconazole ion exchanger and the electromotive force (EMF) was measured by the potentiometric method. The iodide ion ...

متن کامل

Simple, Robust, and Plasticizer-Free Iodide-Selective Sensor Based on Copolymerized Triazole-Based Ionic Liquid.

Novel solid-contact iodide-selective electrodes based on covalently attached 1,2,3 triazole ionic liquid (IL) were prepared and investigated in this study. Triazole-based IL moieties were synthesized using click chemistry and were further copolymerized with lauryl methacrylate via a simple one-step free radical polymerization to produce a "self-plasticized" copolymer. The mechanical properties ...

متن کامل

Design and Fabrication of PVC Membrane Electrode Based on Netural Ligand (E)-N'-(1-(2-Hydroxyphenyl)Ethylidene)Benzohydrazi for Teramadol hydrochloride Measurement in Drugs and Biological Fluids

Here, a simple, quick, Low cost and sensitive Potentiometric method is described for tramadol hydrochloride measurement using .PVC membrane electrode based on neutral ligand (E)-N'-(1-(2-hydroxyphenyl)ethylidene)benzohydrazid. Besides, effect of various parameters like ionic additives, membrane solvent and pH on the Potentiometric response of the electrode are investigated. The best electrode p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Endocrinologia japonica

دوره 33 6  شماره 

صفحات  -

تاریخ انتشار 1986