Dynamic RSA for the evaluation of inducible micromotion of Oxford UKA during step-up and step-down motion

نویسندگان

  • Kristian Horsager
  • Bart L Kaptein
  • Lone Rømer
  • Peter B Jørgensen
  • Maiken Stilling
چکیده

Background and purpose - Implant inducible micromotions have been suggested to reflect the quality of the fixation interface. We investigated the usability of dynamic RSA for evaluation of inducible micromotions of the Oxford Unicompartmental Knee Arthroplasty (UKA) tibial component, and evaluated factors that have been suggested to compromise the fixation, such as fixation method, component alignment, and radiolucent lines (RLLs). Patients and methods - 15 patients (12 men) with a mean age of 69 (55-86) years, with an Oxford UKA (7 cemented), were studied after a mean time in situ of 4.4 (3.6-5.1) years. 4 had tibial RLLs. Each patient was recorded with dynamic RSA (10 frames/second) during a step-up/step-down motion. Inducible micromotions were calculated for the tibial component with respect to the tibia bone. Postoperative component alignment was measured with model-based RSA and RLLs were measured on screened radiographs. Results - All tibial components showed inducible micromotions as a function of the step-cycle motion with a mean subsidence of up to -0.06 mm (95% CI: -0.10 to -0.03). Tibial component inducible micromotions were similar for cemented fixation and cementless fixation. Patients with tibial RLLs had 0.5° (95% CI: 0.18-0.81) greater inducible medio-lateral tilt of the tibial component. There was a correlation between postoperative posterior slope of the tibial plateau and inducible anterior-posterior tilt. Interpretation - All patients had inducible micromotions of the tibial component during step-cycle motion. RLLs and a high posterior slope increased the magnitude of inducible micromotions. This suggests that dynamic RSA is a valuable clinical tool for the evaluation of functional implant fixation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Use of Radiostereometric Analysis in Fractures of the Distal Radius

Rami Madanat The use of radiostereometric analysis in fractures of the distal radius: From phantom models to clinical application Orthopaedic Research Unit, Department of Orthopaedic Surgery and Traumatology, University of Turku, Turku, Finland. Annales Universitatis Turkuensis, Medica-Odontologica, 2011, Turku, Finland. Radiostereometric analysis (RSA) is a highly accurate method for the measu...

متن کامل

مقایسه دو روش تحریک تخمک گذاری در مبتلایان به تخمدان پلی کیستیک مقاوم به کلومیفن درسیکل IUI با استفاده از گنادوتروپینLow-dose step-up و Step-down

Introduction: Polycystic ovary syndrome(PCOS) is one of the most common cause of infertility in women. clomiphene is the first line of treatment. however 20% of patients are resistant to clomiphene. because of follicular hypersensitivity to gonadotropins in pcod, multiple follicular growth and development occurs which is cause of OHSS and multiple pregnancy. Our aim of this random and clinical ...

متن کامل

Sliding Mode Control of a Bidirectional Buck/Boost DC-DC Converter with Constant Switching Frequency

In this paper, sliding mode control (SMC) for a bidirectional buck/boost DC-DC converter (BDC) with constant frequency in continuous conduction mode (CCM) is discussed. Since the converter is a high-order converter, the reduced-order sliding manifold is exploited. Because of right-half-plan zero (RHPZ) in the converter’s duty ratio to output voltage transfer function, sliding mode current...

متن کامل

Influences of temporal evolution of ground motion frequency content on developed dynamic ratcheting in SDOF systems

Dynamic Ratcheting (DR) is a nonlinear dynamic phenomenon occurring in hysteretic damping systems. It means the structural plastic deformation increases asymmetrically in successive cycles under an earthquake excitation. Although it is generally recognized that DR is closely related to the frequency contents of an earthquake excitation applied to thestructure, no targeted analysis has bee...

متن کامل

Reverse Shoulder Arthroplasty is Superior to Hemiarthroplasty for Cuff Tear Arthropathy with Preserved Motion

Background: It is unclear whether hemiarthroplasty (HA) or reverse shoulder arthroplasty (RS) are superior for patientswith cuff tear arthropathy (CTA) and preserved preoperative motion (elevation >90˚).Methods: This was a retrospective, single institution study. Patients who underwent RSA or HA for CTA were included ifthey had preserved preoperative motion with a minimum of 2...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 88  شماره 

صفحات  -

تاریخ انتشار 2017