An implantable intraocular pressure transducer: initial safety outcomes.

نویسندگان

  • Samir Melki
  • Amit Todani
  • George Cherfan
چکیده

IMPORTANCE To our knowledge, this is a report of the first implantation of a wireless intraocular pressure transducer (WIT) in a human eye. OBJECTIVE To report preliminary safety data on the WIT. DESIGN, SETTING, AND PARTICIPANT In an institutional setting, a patient with open-angle glaucoma consented to be the recipient of the WIT in one eye in an interventional study design. INTERVENTIONS The WIT was implanted into the ciliary sulcus following extracapsular cataract extraction and "in the bag" intraocular lens implantation. The patient was monitored postoperatively for 18 months. MAIN OUTCOMES AND MEASURES Any adverse events. RESULTS There were no complications noted during the WIT insertion or postoperatively. No persistent intraocular inflammation, pigment dispersion, or angle narrowing was noted. CONCLUSIONS AND RELEVANCE The WIT was well tolerated in the eye and no overt signs of toxicity or other adverse events were noted. This may allow the constant monitoring of intraocular pressure in the future.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reliable intraocular pressure measurement using automated radio-wave telemetry

PURPOSE To present an autonomous intraocular pressure (IOP) measurement technique using a wireless implantable transducer (WIT) and a motion sensor. METHODS The WIT optical aid was implanted within the ciliary sulcus of a normotensive rabbit eye after extracapsular clear lens extraction. An autonomous wireless data system (AWDS) comprising of a WIT and an external antenna aided by a motion se...

متن کامل

Posterior Chamber Toric Implantable Collamer Lenses – Literature Review

Posterior Chamber Phakic Toric Implantable Collamer Lenses have become increasingly used to correct refractive error associated with astigmatism. These devices are claimed to provide high efficacy in terms of refractive correction. This book chapter is an updated review on the safety and effectiveness and potential complications of the toric implantable collamer lens (Toric ICL) published in pe...

متن کامل

Posterior chamber collagen copolymer phakic intraocular lens with a central hole for moderate-to-high myopia

The purpose of this article is to evaluate the clinical outcomes of a posterior chamber phakic intraocular lens (pIOL) (Visian Implantable Collamer Lens V4c) for the correction of moderate to high myopia in Chinese eyes.The article is designed as a retrospective case series.This study included the first consecutive eyes that had implantation of a new pIOL design with a central hole, at our depa...

متن کامل

Nanoarray-enhanced Implantable Intraocular Pressure Sensor with Remote Optical Readout

We demonstrate a compact implantable intraocular pressure sensor with remote optical readout for glaucoma research and patient management. Using broadband white light between 7801150nm, we excite the sensor’s pressure-sensitive optomechanical cavity and detect the reflected light, whose optical signature changes as a function of intraocular pressure. When measured inside an artificial pressure ...

متن کامل

Measurement of Intraocular Pressure in a Porcine Ex Vivo Model Eye

Aims: To compare the pressure inside and outside the pig eye in relation to the location of cannulation for the injection of liquid into the anterior or vitreous chamber. Method: Eleven enucleated pig eyes were used. 46 measurements of intraocular pressure IOP were taken with a Perkins tonometer when the eye was cannulated in the anterior chamber. 49 measurements were taken when the eye was can...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JAMA ophthalmology

دوره 132 10  شماره 

صفحات  -

تاریخ انتشار 2014