Identification and antimicrobial susceptibility testing of clinical isolates of nonfermenting gram-negative bacteria by the Phoenix Automated Microbiology System.
نویسندگان
چکیده
The Phoenix Automated Microbiology System (Becton Dickinson, Sparks, MD) was evaluated for its ability to identify nonfermenting gram-negative pathogens and measure their drug susceptibility. Isolates producing rare extended-spectrum beta-lactamases (PER-1, IMP-2, VIM-1, and VIM-2) were included in the study. Species identification was compared to that given by the ATB System (bio-Mérieux, Marcy l'Etoile, France), whereas susceptibility results were compared to those produced by a reference broth microdilution test (panels manufactured by Pasco Laboratories, Becton Dickinson). The Phoenix system consistently identified all isolates of Pseudomonas aeruginosa (n = 55) and Stenotrophomonas maltophilia (n = 28), while in other cases species agreement was obtained for 47/53 isolates (Acinetobacter baumannii, 29/31; Pseudomonas putida, 10/11; Burkholderia cepacia, 6/7; and Pseudomonas fluorescens, 2/4). Overall, the Phoenix and ATB systems gave equal results in 130/136 cases (95.6%). For two isolates, consistent identification was obtained at the genus level, thus bringing the cumulative agreement to 97.1%. MIC values (interpreted according to NCCLS guidelines) gave essential and categorical agreement in 94.2% and 93.1% of cases, respectively. Minor and major errors were 5.1% and 5.2%, respectively. No very major errors were produced. The mean time to results (TTR) for the Phoenix system was 14.8 +/- 1.6 h (mean +/- SD), with the shortest TTR being observedfor A. baumannii (13.0 +/- 1.8 h) and the longest one for P. aeruginosa (15.6 +/- 1.2 h). In conclusion, the Phoenix system performed rapidly and correctly in the identification of clinical isolates of important opportunistic pathogens and in measuring their susceptibility to antipseudomonal drugs.
منابع مشابه
Comparison of an Automated System with Conventional Identification and Antimicrobial Susceptibility Testing
The present study was designed to compare a fully automated identification/antibiotic susceptibility testing (AST) system BD Phoenix (BD) for its efficacy in rapid and accurate identification and AST with conventional manual methods and to determine if the errors reported in AST, such as the (very major errors) VME (false susceptibility), (major errors) ME (false resistance), and (minor errors)...
متن کاملEvaluation of the automated phoenix system for potential routine use in the clinical microbiology laboratory.
A comparative study was designed to evaluate the identification (ID) and antimicrobial susceptibility testing (AST) performances of the BD Phoenix Automated Microbiology System (Becton Dickinson Diagnostic Systems [BD], Pont de Claix, France). A total of 305 single clinical isolates were collected, and comparisons were made with routine manual methods in use in our microbiology laboratories. Th...
متن کاملPerformance evaluation of the BD phoenix automated microbiology system in meropenem susceptibility testing of clinical Pseudomonas aeruginosa isolates.
I the management of pseudomonal infections, carbapenems are among the most potent and the last-line of antibiotics. Therefore, reliable in vitro susceptibility testing of the clinical isolates of Pseudomonas aeruginosa (P. aeruginosa) against carbapenems is of paramount importance for the healthcare outcome.1 However, in the post-market evaluations, it has been demonstrated that not all the tes...
متن کاملFrequency of Pathogens and Antimicrobial Susceptibility of Bacteria Isolated from Bloodstream Infections
Background and Objectives: Blood stream infections cause significant morbidity and mortality in the world. In this study, we aimed at describing the organisms responsible for septicemia in 2006-2007 and their antimicrobial susceptibility that might lead to proper selection of antimicrobial agents in hospitalized patients with suspected sepsis. Materials and Methods: Microbiology reports of ...
متن کاملCritical evaluation of the AutoMicrobic system gram-negative identification card for identification of glucose-nonfermenting gram-negative rods.
During a 6-month study we critically evaluated the accuracy of the AutoMicrobic system Gram-Negative Identification Card (Vitek Systems, Inc., Hazelwood, Mo.) in identifying glucose-nonfermenting gram-negative bacilli by testing 419 selected isolates in parallel with a conventional reference method. Of 356 isolates included in the AutoMicrobic system profile, a total of 307 (86.2%) were correct...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The new microbiologica
دوره 25 3 شماره
صفحات -
تاریخ انتشار 2002