Radiographic analysis of fusion success with Integra Collagen Ceramic Matrix, as compared to autograft use, in posterolateral lumbar spine arthrodesis
نویسنده
چکیده
Study Design: Retrospective, single center, non-randomized study. Objectives: To evaluate the efficacy of Integra Collagen Ceramic Matrix (Collagen / β-TCP Composite) bone void filler in posterolateral lumbar fusions. Methods: All patients treated with Integra Collagen Ceramic Matrix (CCM) putty and/or strip during posterior or transforaminal lumbar fusion surgery between April 2007 – December 2007, and who had CT Scan images at 1 year post surgery were considered for inclusion in the study. Medical records of these patients were analyzed, and data was collected on all subjects who met the eligibility requirements. Fine-cut CT scans with sagittal and coronal reconstructions were interpreted by an independent radiologist blinded to treatment. Results: Of the 18 patients, 9 patients (50%) underwent single level fusion procedures, 5 patients (28%) had 2-level fusion surgery, 3 patients (17%) had 3-level surgery and 1 patient (5%) underwent a 4-level procedure. Fusion rates were 100% for all evaluable single level and 2-level cases. Overall fusion rate was 93.5% (29/31) of all evaluable levels. When comparing the two posterolateral sides, the autograft side and Integra CCM side resulted in nearly identical fusion rates: 29 of 31 evaluable levels (93.5%) at the autograft side and 28 of 30 evaluable levels at the Integra CCM side (93.3%) No significant differences were observed for the fusion scores in patients that received Integra CCM Putty versus Integra CCM Strip. There were no Adverse Device Effects noted. Two patients experienced Serious Adverse Events resulting in prolonged hospitalization. These SAEs were unrelated to the devices used, and resolved without residual effect. None of the 18 patients required re-operations for revision, removal or supplemental fixation. Conclusion: Integra CCM is an effective and safe alternative for the use of autograft in posterolateral lumbar fusions, with fusion rates similar or better than those reported with autograft and other bone graft alternatives.
منابع مشابه
Simple carrier matrix modifications can enhance delivery of recombinant human bone morphogenetic protein-2 for posterolateral spine fusion.
STUDY DESIGN A nonhuman primate lumbar intertransverse process arthrodesis model was used to evaluate modifications to a plain collagen sponge to deliver recombinant human bone morphogenetic protein-2 (rhBMP-2). OBJECTIVES To evaluate the feasibility of enhancing the delivery of rhBMP-2 with the established collagen sponge carrier by adding biphasic ceramic phosphate (BCP) granules (15% hydro...
متن کاملA prospective randomized study of posterolateral lumbar fusion using osteogenic protein-1 (OP-1) versus local autograft with ceramic bone substitute: emphasis of surgical exploration and histologic assessment.
STUDY DESIGN A prospective, randomized and controlled study. OBJECTIVES To evaluate the osteoinductive property of Osteogenic Protein-1 (OP-1 or BMP-7) and fusion rate in human instrumented posterolateral lumbar fusion through radiographic examination, surgical exploration, and histologic assessment. SUMMARY OF BACKGROUND DATA The use of osteoinductive agents is a current topic in spinal fu...
متن کاملUse of Nanocrystalline Hydroxyapatite With Autologous BMA and Local Bone in the Lumbar Spine
STUDY DESIGN A retrospective, multicenter, medical record review and independent analysis of computed tomographic scans was performed in 46 patients to determine radiographic arthrodesis rates after 1-segment, 2-segment, or 3-segment instrumented posterolateral fusions (PLF) using autograft, bone marrow aspirate (BMA), and a nanocrystalline hydroxyapatite bone void filler (nHA). OBJECTIVE To ...
متن کاملInstrumented Lumbar Corpectomy and Spinal Reconstruction Comparing rhBMP-2/Compression-Resistant Matrix, rhBMP-2/Absorbable Collagen Sponge/Ceramic Granules Mixture, and Autograft in Two Different Devices: A Study in Sheep.
STUDY DESIGN Fusion success with rhBMP-2 and autograft in titanium or PEEK corpectomy devices was evaluated in a sheep lumbar corpectomy model. The 6 treatment groups included titanium mesh or PEEK corpectomy devices filled with rhBMP-2 on a compression-resistant matrix (CRM) carrier; rhBMP-2 in a morselized absorbable collagen sponge (ACS) carrier combined with resorbable ceramic granules; and...
متن کاملCeramic-Based Bone Grafts as a Bone Grafts Extender for Lumbar Spine Arthrodesis: A Systematic Review
Study Design Systematic review. Objective Ceramic-based bone grafts have been widely utilized to reduce the need for iliac crest bone grafting given the complications associated with the harvest of iliac crest autograft. As a family, ceramics vary widely based on differences in composition, manufacturing, porosity, and structure, which may ultimately affect their efficacy. This article reviews ...
متن کامل