Accuracy and Reliability of Computed Tomography and Magnetic Resonance Imaging Compared to True Anatomic Femoral Torsion
نویسندگان
چکیده
BACKGROUND Abnormal torsion of the femur is correlated to lower extremity pathologies. Although computed tomography (CT) scan is the gold standard torsional measurement, magnetic resonance imaging (MRI) is proposed as a viable alternative. Our aim was to determine the accuracy and consistency of MRI and CT femur rotational studies based on 4 described protocols. METHODS Twelve cadaveric femora were stripped of soft tissue before imaging and physical assessment of torsion. Four advanced imaging series were obtained for each specimen: CT with axial cuts of the femoral neck (CT-axial); CT with oblique cuts of the femoral neck (CT-oblique); MRI with axial cuts of the femoral neck (MR-axial); MRI with oblique cuts of the femoral neck (MR-oblique). Anatomic specimens were placed with the posterior femoral condyles flat on a dissection table for assessment of true torsion with digital images. Three independent reviewers performed all measurements, including true torsion, using imaging software. Bland-Altman analysis was repeated with the data from each reviewer. RESULTS Interobserver repeatability for all groups was high at 0.95, 0.87, 0.90, 0.97, and 0.92 for CT-axial, CT-oblique, MR-axial, MR-oblique, and true torsion, respectively. CT-axial had the lowest mean difference from clinical imaging for all three observers (all <1 degree) and held the tightest 95% limits of agreement for 2/3 observers. As torsion increases from neutral, MR-oblique linearly overestimates the rotation compared with true torsion. CT-oblique and MR-axial showed slightly greater differences from true torsion compared with CT-axial, but did not reach clinical significance. CONCLUSIONS CT-axial was both most accurate and reproducible when compared with true torsion of the femur and should be the gold standard imaging modality; however, both MR-axial and CT-oblique were accurate to a level that is likely less than clinical significance. MR-axial images should be used in clinical situations where radiation exposure needs to be limited. MR-oblique images can overestimate true antetorsion and should not be used. CLINIC SIGNIFICANCE CT-axial followed by MRI-axial is the most accurate and consistent in measuring true torsion of the femur.
منابع مشابه
Bimodal magnetic resonance imaging-computed tomography nanoprobes: A Review
Bimodal imaging combines two imaging modalities in order to benefit from their advantages and compensate the limitations of each modality. This technique could accurately detect diseases for diagnostic purposes. Nanoparticles simultaneously offer diagnostic data via various imaging modalities owing to their unique properties. Moreover, bimodal nanoprobes could be incorporated into theranostic s...
متن کاملGenerating Synthetic Computed Tomography and Synthetic Magnetic Resonance (sMR: sT1w/sT2w) Images of the Brain Using Atlas-Based Method
Introduction: Nowadays, magnetic resonance imaging (MRI) in combination with computed-tomography (CT) is increasingly being used in radiation therapy planning. MR and CT images are applied to determine the target volume and calculate dose distribution, respectively. Since the use of these two imaging modalities causes registration uncertainty and increases department w...
متن کاملDevelopment of an Advanced Optical Coherence Tomography System for Radiation Dosimetry
Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...
متن کاملArtifacts of Titanium, Zirconium, and Binary Titanium-Zirconium Abutments in Compute Tomography, Cone Beam Computed Tomography, and Magnetic Resonance Imaging
Aim: The aim of this in vitro study was to evaluate imaging artifacts induced by Titanium, Zirconium, Titanium-Zirconium abutments in CT, MRI and CBCT imaging modalities.Methods: A 4×8mm titanium fixture was inserted in a dry human mandible. Titanium, Zirconium and Titanium–Zirconium abutments measuring 10.5 mm in height are located on the fixture, one by one. Each abutment was scan...
متن کاملApplication of computed tomography and magnetic resonance imaging fusion images for delineating gross tumor volume in three-dimensional conformal radiotherapy of nasopharyngeal carcinoma
Background: To evaluate computed tomography (CT) and magnetic resonance imaging (MRI) fusion images for delineating gross tumor volume (GTV) in three-dimensional conformal radiotherapy (3D-CRT) of nasophanrygeal carcinoma (NPC), and compare treatment outcomes between CT- and CT+MRI-based targets. Materials and Methods: A total of 120 NPC patients treated with 3D-CRT were included, in which, 60 ...
متن کامل