A Patient-specific Qa Procedure for Moving Target Irradiation in Scanned Ion Therapy
نویسندگان
چکیده
Three-dimensional (3D) pencil-beam scanning technique has been utilized since 2011 in NIRS-HIMAC. Beam delivery system and treatment planning software (TPS) require dosimetric patient-specific QA to check each individual plan. Any change in the scanned beams will result in a significant impact on the irradiation dose. Therefore, patient-specific QA for moving target irradiation requires additional procedure. In an additional QA for moving target irradiation, we placed 2D ionization chamber on the PMMA plate tilted with respect to the beam axis. The PMMA plate was set on the stage of the moving phantom. The moving phantom was moved according to patient data. We measured the dose distribution for both the static target and the moving target. We compared the results for the moving target with those for the static targets by means of a gamma index analysis. In the additional patient-specific QA, the gamma analysis between the moving and static targets showed the good agreement. We confirmed that this new technique was a beneficial QA procedure for moving target irradiation.
منابع مشابه
A Specific Patient Quality Assurance (PSQA) procedure for a Co-60 source based High Dose Rate Brachytherapy
Introduction: In radiation therapy, accurate dose determination and precise dose delivery to the tumor are directly associated with better treatment outcomes in terms of higher tumor control and lower post radiation therapy complications. The current study aims the development and clinical application of the Patient Specific Quality Assurance (PSQA) procedures for nasopharyngea...
متن کاملQuality Assurance test of the real-time beam tracking system
For radiotherapy with external beams, quality assurance (QA) of beam delivery is mandatory. Dynamical irradiation which changes parameters of beam delivery devices during the irradiation has to be assessed with a great caution. At GSI a dynamic beam delivery system, so called beam tracking system [1] was developed and integrated into the GSI therapy system [2] to irradiate moving tumours with i...
متن کاملInvestigation of tumor motion influence on applied dose distribution in conventional proton therapy vs. IMPT a 4D Monte Carlo simulation study
Background: in radiation treatment of moving targets located in thorax region of patient body, the delivered dose does not match with the planned treatment, resulting in some over and under dosage in the tumor volume, as a function of motion magnitude and frequency. Several efforts have been done to investigate the target motion effects on dose distribution in the target and surrounding normal ...
متن کامل4D optimization of scanned ion beam tracking therapy for moving tumors.
Motion mitigation strategies are needed to fully realize the theoretical advantages of scanned ion beam therapy for patients with moving tumors. The purpose of this study was to determine whether a new four-dimensional (4D) optimization approach for scanned-ion-beam tracking could reduce dose to avoidance volumes near a moving target while maintaining target dose coverage, compared to an existi...
متن کامل4D in-beam PET of moving targets for different irradiation scenarios
Introduction Ion therapy allows a high precision, tumor conformal dose application but it is very sensitive to density changes along the beam path. Intra-fractional tumor motion due to respiration increases the risk of an incorrect irradiation and thus requires a reliable dosimetry as it was done by means of 3D in-beam PET for more than 400 patients at the experimental heavy ion treatment facil...