MRI of the Ex-PRESS stainless steel glaucoma drainage device.

نویسندگان

  • Leonard K Seibold
  • Ronald A L Rorrer
  • Malik Y Kahook
چکیده

AIM To evaluate the magnetic properties of the Ex-PRESS stainless steel glaucoma drainage device during MRI. DESIGN Experimental study. METHODS The Ex-PRESS glaucoma drainage device (316L stainless steel) was examined for magnetic field interactions under standard 1.5, 3.0, and 4.7 T MRI scanning protocols. Testing included measurements of translational and rotational motion of the device induced by static magnetic fields. In addition, the change in the temperature of the device was measured to assess the presence of radiofrequency heating of the stainless steel device. MAIN OUTCOME MEASURES Degree of angular deflection, device displacement and rotation, and change in temperature. RESULTS During induced torque testing, displacement did not occur under 1.5 and 3.0 T conditions, although a significant amount of displacement occurred in the 4.7 T environment. Increasing amounts of angular deflection were demonstrated at all three field strengths. We did not record significant temperature changes during brain MRI sequences at any of the three MRI strengths. CONCLUSIONS The Ex-PRESS glaucoma drainage device, manufactured from grade 316L stainless steel, does move in the presence of high magnetic fields. The clinical significance of this finding and translation to in vivo conditions are not currently known. Further studies are needed to better understand how patients might be affected by the magnetic properties of this device post implantation and how patients should be counselled in regards to safety of MRI in the early and late postoperative period.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long term effect on IOP of a stainless steel glaucoma drainage implant (Ex-PRESS) in combined surgery with phacoemulsification.

AIM To evaluate the efficacy and safety of a stainless steel miniature glaucoma drainage device (Ex-PRESS R50) for the surgical treatment of primary open angle glaucoma (POAG) and cataract when combined with phacoemulsification. METHODS Clinical, prospective, multicentre, single treatment arm, non-randomised, non-masked study. The Ex-PRESS device was implanted at the limbus under a conjunctiv...

متن کامل

Ex-PRESS shunt for choroidal fluid drainage in uveal effusion syndrome type 2: a potentially novel technique.

Uveal effusion syndrome (UES) was reported by Schepens and Brockhurst in 1963,1 and later described as a nanophthalmic disorderwith a scleral abnormality.2 Gass3 described idiopathicUES and hypothesized that the causewas a congenital anomalyof the sclera and vortex veins that was related to aging, hormonal changes, or impairment of the permeabilityof the sclera.Using histologicalmethods,Trelsta...

متن کامل

Update on Tube-Shunt Procedures for Glaucoma

Present-day glaucoma implants, i.e., long-tube implants, were introduced by Molteno et al. in 1976 [31]. !e most commonly used implants include Molteno and Ahmed singleand doubleplate implants, and the Baerveldt and Krupin implants. All implants are long-tube implants based on the original Molteno design. !e Ahmed and Krupin implants are valved implants. !e most recent addition to tube-shunt de...

متن کامل

Ex-PRESS Glaucoma Filtration Device: Theory, Technique and Results

The Ex-PRESS glaucoma filtration device (Alcon Laboratories, Fort Worth, TX , USA) is designed to drain aqueous fluid from the anterior chamber to the subconjunctival space and form a filtration bleb, akin to a trabeculectomy. In this article we will review the surgical indications, preoperative evaluation, surgical techniques and postoperative considerations of this ophthalmic device. J Emmetr...

متن کامل

New ab interno technique for removal of iris-embedded EX-PRESS shunt and chronic eye pain caused by shunt malpositioning.

The EX-PRESS shunt (Alcon Laboratory) is a stainless steel implant designed to shunt aqueous from the anterior chamber to the subconjunctival space.Thedevice isplacedundera scleral flap,with the lumenideallypositionedparallel to the iris. A properly positioned EX-PRESS shunt creates acontrolledcommunicationbetween the anterior chamber and the bleb.1 Several shunt-specific complications havebeen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 95 2  شماره 

صفحات  -

تاریخ انتشار 2011