OBJECTIVES Maximal graft flow acceleration (max df/dt) determined by transit-time flowmetry (TTFM) in the diastolic phase was assessed as a possible predictor of graft failure in coronary artery bypass patients. METHODS Max df/dt was retrospectively measured in 57 in situ left internal thoracic artery grafts. TTFM data were fitted to a 5-polynomial curve, which was derived from the first-derivative curve to measure max df/dt (5-polymial max df/dt). Abnormal TTFM was defined as a mean flow of <15 ml/min, pulsatility index of >5 or diastolic filling ratio of <50%. Postoperative coronary angiography (CAG) or multidetector computed tomography (MDCT) was performed within 1 year after surgery. The grafts were classified into four groups: Normal TTFM/Patent MDCT/CAG (N/P), Normal TTFM/Failing MDCT/CAG (N/F), Abnormal TTFM/Patent MDCT/CAG (Ab-N/P) and Abnormal TTFM/Failing MDCT/CAG graft (Ab-N/F). RESULTS By TTFM, 34 grafts were normal, 5 of which were occluded on CAG, and 23 grafts were abnormal, six of which were occluded on CAG. There were significant differences in 5-polynomial max df/dt between each group pair (P < 0.05, Mann-Whitney U-test) except for the N/F:Ab-N/P group pair; especially, 5-polynomial max df/dt was significantly lower in the Ab-N/F group compared with the other groups (Ab-N/F: 0.89 ± 0.41 vs N/P: 4.74 ± 3.18, N/F: 2.23 ± 0.65, Ab-N/P: 2.70 ± 1.31 ml/s(2), P < 0.01, Mann-Whitney U-test). The sensitivity and specificity of 5-polynomial max df/dt were, respectively, 72.7 and 80.4% (cut-off value, 1.918 ml/s(2)) for all grafts and 100 and 88.2% (cut-off value, 1.273 ml/s(2)) for abnormal TTFM grafts. CONCLUSIONS The TTFM 5-polymial max df/dt value in the early diastolic phase may be a promising predictor of future graft failure.
منابع مشابه
eComment. Postoperative rise in serum creatinine following coronary artery bypass grafting: how is this best measured and what is its significance?
et al. T graft with the right internal thoracic artery to left internal thoracic artery versus the left internal thoracic artery and radial artery: flow dynamics in the internal thoracic artery main stem. A new pattern for using both thoracic arteries to revascularize the entire heart: the pi-graft. Effects of heart rate on phasic Y-graft blood flow and flow reserve in patients with complete ar...
متن کاملBlood flow in composite arterial grafts and effect of native coronary flow.
BACKGROUND Total arterial coronary revascularization can be achieved by joining arteries together as a composite graft with the proximal left internal mammary artery as the only source of blood inflow. Proof of the capacity of this composite conduit to provide adequate blood flow to the coronary circulation is required. METHODS The radial artery was anastomosed to the left internal mammary ar...
متن کاملA randomized comparison of flow characteristics of semiskeletonized and pedicled internal thoracic artery preparations in coronary artery bypass
BACKGROUND Harvesting the internal thoracic artery (ITA) with semiskeletonization is an alternative technique between conventional wide pedicle and skeletonization. It is almost as simple as pedicle harvesting; however, it is supposed to provide the advantage of graft flow and length. Since the heart is unique being the only organ which is perfused during diastole, for comparing the intraoperat...
متن کاملPreserved autoregulation of coronary flow after off-pump coronary artery bypass grafting: retrospective assessment of intraoperative transit time flowmetry with and without intra-aortic balloon counterpulsation
BACKGROUND Intra-aortic balloon pumping (IABP) markedly increases graft flow after coronary artery bypass grafting (CABG) with cardiopulmonary bypass. We sought to delineate the effects of IABP on graft flow after off-pump CABG (OPCAB). METHODS The clinical records of 32 patients (25 male, 7 female; mean age: 70 ± 9 years) who underwent OPCAB with IABP between January 2011 and May 2015 were r...
متن کاملCompetitive flow and arterial graft a word of caution.
reliable, exclusively in appropriately selected situations. In creation of bypass grafts, durable completeness of revascularization and function of the ITA to the LAD bypass should not be compromised. We would suggest that the balanced bypass flow toward the LAD and the RCA is noticeably important to achieve an entire patency of the Y-graft for three-vessel regions. This study is not conclusive...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Interactive cardiovascular and thoracic surgery
دوره 20 4 شماره
صفحات -
تاریخ انتشار 2015