Ultracentrifugation in swinging-bucket and fixed-angle rotors evaluated for isolation and determination of high-density lipoprotein subfractions HDL2 and HDL3.

نویسندگان

  • P N Demacker
  • D F van Sommeren-Zondag
  • A F Stalenhoef
  • P M Stuyt
  • A van't Laar
چکیده

We evaluated the density-gradient ultracentrifugation method in a swinging-bucket rotor (Anal Biochem 111, 149-157, 1981) in a slightly modified version for isolation and determination of high-density lipoprotein (HDL) subfractions. We prestained the serum with Coomassie Brilliant Blue R, which did not change the hydrated densities of the lipoproteins, and after only 2.2 X 10(8) gav . min obtained an equilibrium distribution of the lipoproteins along the gradient. The density distribution of the HDL of 120 sera obtained from apparently healthy persons and from patients with different types of hyperlipoproteinemia was bimodal. The HDL2 could be isolated in the density range 1.072-1.098 kg/L and the HDL3 at 1.100-1.176 kg/L, the latter fraction being more heterogeneous. At a solvent density of 1.100 we obtained similar results for HDL2-and HDL3-cholesterol by ultracentrifugation in two different fixed-angle rotors with tube angles of 15 degrees or 35 degrees. Independent of the rotor and the ultracentrifugation technique, subfractionation at d = 1.100 resulted in more distinct stained entities than ultracentrifugation at d = 1.125. In the swinging-bucket rotor procedure, interference by sinking pre-beta-lipoproteins was minimized because, having hydrated densities between 1.058 and 1.075, they could be removed without aspirating the HDL2. The method is both accurate and precise. For HDL2- and HDL3-cholesterol determined in a thawed frozen serum pool, CVs were 8.8 and 6.3%, respectively (n = 18).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the dual-precipitation method for determination of cholesterol in high-density lipoprotein subfractions HDL2 and HDL3 in serum.

We compared the dual-precipitation method for measurement of cholesterol in high-density lipoprotein subfractions HDL2 and HDL3 (Gidez et al., J Lipid Res 1982;23:1206-33) with density-gradient ultracentrifugation in a swinging-bucket rotor (Demacker et al., Clin Chem 1983;29:656-63). The concentration of dextran sulfate 15,000 (DS) needed for optimal accuracy of the HDL2-chol and HDL3-chol val...

متن کامل

Precipitation with polyethylene glycol and density-gradient ultracentrifugation compared for determining high-density lipoprotein subclasses HDL2 and HDL3.

The purpose of this study was to compare quantification of cholesterol in high-density lipoprotein subfractions HDL2 and HDL3 by precipitation with polyethylene glycol (PEG) with that by density-gradient ultracentrifugation. Fresh serum samples from 32 fasting, obese children were analyzed with precipitation reagent "Quantolip" (Immuno AG), and then fractionated with a Beckman TL 100 ultracentr...

متن کامل

جدا سازی HDL2 و HDL3 و مقایسه غلظت کلسترول آنها بین گروه شاهد و مبتلایان به آترواسکلروز

The major Lipoprotein classes are heterogenous. Human serum High-Density-Lipoproteins (HDL) are separated into two major subfractions (HDL2, d=1.063-1.125 g/ml, HDL3, d=1.125-1.210 g/ml) by a simple double precipitation method. There was a strong inverse relation between HDL-Cholesterol (HDL-C) and subfractions HDL2-C and HDL3-C with atherosclerosis. This study demonstrated that HDL-C (P<0.001)...

متن کامل

A dual-precipitation method evaluated for measurement of cholesterol in high-density lipoprotein subfractions HDL2 and HDL3 in human plasma.

The dual-precipitation method for measurement of cholesterol in high-density lipoprotein subfractions HDL2 and HDL3 (Warnick et al., Clin Chem 1982;28:1574) was compared with quantification of cholesterol in HDL2 and HDL3 by zonal ultracentrifugation (Patsch et al., J Lipid Res 1974;15:356-66). For 39 plasma specimens differing widely in their HDL subfraction cholesterol concentration, the coef...

متن کامل

Cholesterol distribution between high-density-lipoprotein subfractions HDL2 and HDL3 determined in serum by discontinuous gradient gel electrophoresis.

We used discontinuous gradients of polyacrylamide gel to determine the high-density-lipoprotein (HDL) subfractions HDL2 and HDL3 of serum lipoproteins. Serum (40 microL) prestained with Sudan Black was electrophoresed in cylindrical tubes over successive layers of 3.5%, 6%, 13%, and 17.5% acrylamide gels in a Tris.glycine buffer (3-4 h, 300 V). Very-low- (VLDL) and low-density lipoprotein (LDL)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 29 4  شماره 

صفحات  -