Blood flow distributions by microsphere deposition methods.
نویسندگان
چکیده
The art and science of the use of deposition markers for the estimation of blood flow distributions throughout the body and within organs is reviewed. Development of diffusible tracer techniques started 50 years ago. Twenty years later, radioactive 15 micron microspheres became the standard marker. Early studies on small animals, fetal sheep in 1967 and rats in 1976, provoked much of the technical development. Needs for avoiding the use of radioactivity, for having long lasting labels, and for providing higher spatial resolution, are driving the continuing exploration of newer techniques using colored and fluorescent microspheres and molecular deposition markers. Strengths and weaknesses of the various methods are compared.
منابع مشابه
Microsphere maps of regional blood flow and regional ventilation.
Systematically mapped samples cut from lungs previously labeled with intravascular and aerosol microspheres can be used to create high-resolution maps of regional perfusion and regional ventilation. With multiple radioactive or fluorescent microsphere labels available, this methodology can compare regional flow responses to different interventions without partial volume effects or registration ...
متن کاملInvited Review HIGHLIGHTED TOPIC Physiological Imaging of the Lung Microsphere maps of regional blood flow and regional ventilation
Robertson HT, Hlastala MP. Microsphere maps of regional blood flow and regional ventilation. J Appl Physiol 102: 1265–1272, 2007. First published December 7, 2006; doi:10.1152/japplphysiol.00756.2006.—Systematically mapped samples cut from lungs previously labeled with intravascular and aerosol microspheres can be used to create high-resolution maps of regional perfusion and regional ventilatio...
متن کاملComparing microsphere deposition and flow modeling in 3D vascular trees.
Blood perfusion in organs has been shown to be heterogeneous in a number of cases. At the same time, a number of models of vascular structure and flow have been proposed that also generate heterogeneous perfusion. Although a relationship between local perfusion and vascular structure has to exist, no model has yet been validated as an accurate description of this relationship. A study of perfus...
متن کاملHigh-resolution imaging reveals a limit in spatial resolution of blood flow measurements by microspheres.
Density of 15-microm microspheres after left atrial application is the standard measure of regional perfusion. In the heart, substantial differences in microsphere density are seen at spatial resolutions <5 ml, implying perfusion heterogeneity. Microsphere deposition imaging permits a superior evaluation of the distribution pattern. Therefore, fluorescent microspheres (FMS) were applied, FMS de...
متن کاملComparison between hydrogen clearance and microsphere technique for rCBF measurement.
Regional cerebral blood flow was measured repeatedly in anesthetized and immobilized cats under various experimental conditions by recording the clearance of inhaled hydrogen with inserted platinum electrodes and by recording the distribution of 15 mu microspheres labeled with 3 different radioisotopes. The values for both methods in normal cortical tissue were comparable (75.7 +/- 23.5 ml/100 ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Cardiovascular research
دوره 45 1 شماره
صفحات -
تاریخ انتشار 2000